PWR-ICE250 Manual
miniDSP Ltd – Hong Kong / Email :
/ Features and Specifications are subject to change without prior notice
P 18
The RMS meter will quickly indicate the average value of the input signal in dBFS (i.e. relative to the full scale of the ADC or 24bit I2S
signal). This meter displays dB full scale (dBFS) values and will saturate at 0dBFS (full scale of the ADC). Do make sure to keep the
signal below 0dBFS (red color) and with enough headroom (say 10dB) to prevent saturation during the typical audio peaks of a music
source.
2.9.4
Channel Mode
The PWR-ICE 250 runs a 1 x IN, 2 x OUT DSP configuration and will operate under 3 modes selectable from the GUI of the plug-in.
Channel 1 (L): Mono input from RCA unbalanced Left, analog XLR input 1 or Digital AES input Left
Channel 2 (R): Mono input from RCA unbalanced Right, analog XLR input 2 or Digital AES input Right
Mixed L&R (Mixed): Mixed input of RCA unbalanced Left & Right, analog XLR input 1& 2 or Digital AES input left&right.
Level control
RMS meter
monitoring
Per channel
PEQ button
Custom
Label
Source selection