Designation
Description
Abbr. C3
C4
C5
C6
Unit
Nominal ambient
temp. range
to hold the speciied perfor-
mance
B
T
-10 to +55
°C
Service temperature
range
permissible for continuous ope-
ration without damage
B
Tu
-40 to +95
°C
Storage temperature
range
without electrical and mechani-
cal stress
B
Ti
-40 to +95
°C
Permissible eccentri-
city
permissible displacement from
nominal load line at the head of
the load cell
S
ex
5
mm
Vibration resistance Resistance against oscillations
(IEC 60068-2-6 Fc)
20 g, 100 h, 10 to 150 Hz
Barometric pressure
inluence
inluence of barometric pressu-
re on output
PK
Smin
420
g/kPa
elastic deformation under maxi-
mum capacity
E
max
= 12.5 t
s
nom
0.2
0.2
…
…
mm
E
max
= 20 t
s
nom
0.4
mm
E
max
= 25 t
s
nom
0.5
mm
E
max
= 30 t
s
nom
0.5
mm
E
max
= 50 t
s
nom
0.8
mm
E
max
= 60 t
s
nom
0.9
mm
Nominal delection
E
max
= 75 t
s
nom
1.1
mm
Deinitionen nach VDI/VDE 2637
Die angegebenen technischen Daten dienen allein zur Produktbeschreibung und sind
nicht als zugesicherte Eigenschaften im Rechtssinne aufzufassen.
NTEP: min. scale interval of the load cells v
min
Type
Divisi-
ons
n
max
12.5 t
20 t
25 t
30 t
50 t
60 t
75 t
Unit
Class III
L Multi-
ple
C3
10000
0.43
0.48
0.60
0.71
1.19
1.43
1.79
kg
Weighbridge Load Cell PR 6221
4 Speciications
Minebea Intec
EN-12