Terminal contacts
1–4
- sense (load cells)
Sense -
black
Terminal contact
IND
- sense (connection cable)
Terminal contacts
1–4
+ sense (load cells)
Sense +
white
Terminal contact
IND
+ sense (connection cable)
Terminal contacts
1–4
+ supply voltage (load cells)
red
Terminal contact
IND
+ supply voltage (connection cable)
Terminal contacts
1–4
Screen (load cells)
Screen
yellow
Terminal contact
IND
Screen (connection cable)
J1
Jumper
J2
Jumper
Connects the load cell supply line to the
sense line. Both jumpers must be opened
when 6-wire load cell cables are used.
J3
Jumper
Connects the load cell cable screen to the
connection cable screen.
4.3 Connecting load cells with a 4-wire cable
Upon delivery, jumpers J1 and J2 are closed between terminals "Sense -/Supply -" and
"Sense +/"; this means that the junction box is prepared for load cells with 4-wire
cables; see Chapter
.
4.4 Connecting load cells with a 6-wire cable
If the junction box will be used for load cells with 6-wire cables, jumpers J1 and J2 must be
open between terminals "Sense -/Supply -" and "Sense +/."
Cable Junction Box PR 6130/34Sa
4 Installation and connection information
EN-12
Minebea Intec
Summary of Contents for PR 6130/34Sa
Page 17: ...Connection example 5 Cable connections Cable Junction Box PR 6130 34Sa Minebea Intec EN 15 ...
Page 24: ...8 1 MEU17042 Cable Junction Box PR 6130 34Sa 8 Certificates EN 22 Minebea Intec ...
Page 25: ...8 Certificates Cable Junction Box PR 6130 34Sa Minebea Intec EN 23 ...
Page 26: ...Cable Junction Box PR 6130 34Sa 8 Certificates EN 24 Minebea Intec ...
Page 27: ...8 Certificates Cable Junction Box PR 6130 34Sa Minebea Intec EN 25 ...
Page 28: ...Cable Junction Box PR 6130 34Sa 8 Certificates EN 26 Minebea Intec ...
Page 29: ...8 Certificates Cable Junction Box PR 6130 34Sa Minebea Intec EN 27 ...