1

INTERNAL PADDLES INSTRUCTIONS FOR USE

Statement

SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD.

 (hereinafter 

called Mindray) owns the intellectual property rights to this product and this 

manual. Disclosure of the information in this manual in any manner whatsoever 

without the written permission of Mindray is strictly forbidden. 

This manual provides the instructions necessary to operate the product in accor-

dance with its function and intended use. Observance of this manual is a prereq-

uisite for proper performance and correct operation, and ensures patient and 

operator safety.

Mindray is responsible for the effects on safety, reliability and performance of this 

product, only if:

 

z

the product is used in accordance with the instructions for use.

 

z

this product is not damaged by human factors. Human factors refer to unin-

tentional falling, intentional damaging, etc. 

In the event that it becomes necessary to return a unit to Mindray, please contact 

the Mindray Service Department and obtain a Mindray Customer Service Autho-

rization Number. The Mindray Customer Service Authorization Number must 

appear on the outside of the shipping container. Return shipments will not be 

accepted if the Mindray Customer Service Authorization Number is not clearly 

visible. Please provide the model number, serial number, and a brief description 

of the reason for return. The customer is responsible for freight charges when this 

product is shipped to Mindray for service (including any relevant customs fees or 

other freight related charges).

 

 

and 

 are the registered trademarks or trademarks owned by Mindray 

in China.
©

 2009-2020 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. All rights reserved.

Summary of Contents for MR6501

Page 1: ...Shenzhen Mindray Bio Medical Electronics Co Ltd Internal Defibrillation Paddles Instructions for Use...

Page 2: ......

Page 3: ...ons for use z z this product is not damaged by human factors Human factors refer to unin tentional falling intentional damaging etc In the event that it becomes necessary to return a unit to Mindray p...

Page 4: ...comply with IEC 60601 2 4 for surface area recommendations for defibrillation paddles Warnings z z The internal paddles shall only be used by trained clinical professionals and with Mindray BeneHeart...

Page 5: ...or chipped coating z z Check paddle handles cables and connectors for damaged pins or material deterioration Function Check 1 Turn on the defibrillator and enter the Manual Defib mode 2 Select the app...

Page 6: ...d left ventricle as shown in the figure below 4 Charge the defibrillator by pressing the Charge key on the front panel 5 Make sure no one is touching the patient or anything connected to the patient 6...

Page 7: ...ge from higher energies Cleaning disinfection and Sterilization Clean and sterilize the internal paddles after each use Do not allow the insulating handles or paddle electrodes to dry after use and be...

Page 8: ...internal paddles from the defibrillator 2 Use a volt ohm meter or a digital multimeter to verify the resistance between the test points in the following table Be sure that good electrical contact is m...

Page 9: ...USA restricts this device to sale by or on the order of a physician 1639 Mark of conformity to European Medical Device Directive 93 42 EEC Operation and Storage Environment Operating temperature 0 to...

Page 10: ...fector sterilizer and the detergent z z Open the package just before the use to avoid the sterilized internal paddles being contaminated z z Check the wrap before use Remove the internal paddles from...

Page 11: ...environment Preparation before cleaning No particular requirements Disassembly not required Manual cleaning and disinfection method 1 Dampen the surface of the product with running water prior to cle...

Page 12: ...nutes Packaging Seal the product into a standard pouch that is compatible with moist heat sterilization using the heat sealing machine Ensure that the pack is large enough to contain the paddles witho...

Page 13: ...s materials and machines were used during the validation Cleaning agents Neodisher Dr Weigert Washer disinfector G7895 Miele Protein residue swab Protein residue swab 3M Packaging materials Fully Peel...

Page 14: ...al Park Nanshan Shenzhen 518057 P R China Tel 86 755 81888998 Fax 86 755 26582680 E mail service mindray com cn 518057 24 4007005652 86 755 81888998 86 755 26582680 Shanghai International Holding Corp...