Mindra HK-D07-230-NE1 User Manual Download Page 1

  

 

 

 

 

 

MINDRA GREEN ENERGY LLP 

 

TYPE  2  AC  EV  CHARGER

 

USERS  MANUAL 

Edition

V1.1.0 

Summary of Contents for HK-D07-230-NE1

Page 1: ...MINDRA GREEN ENERGY LLP TYPE 2 AC EV CHARGER USERS MANUAL Edition V1 1 0...

Page 2: ...nformation in this manual to the third party without any authorization To ensure the accuracy the manual has been carefully reviewed If any errors found while using any comments will be welcomed If an...

Page 3: ...contact the manufacturer timely in case of abnormal situations during the operation Maintenance carried out by other personnel except for professional technicians may cause further damage injuries or...

Page 4: ...n and Installation Page 9 References Familiar with the charging process Operation instructions Page 16 Inspection and installation Take the charging pile out of the packing box check the product namep...

Page 5: ...5 3 PROTECTION CHARACTERISTICS 4 5 4 EMC CHARACTERISTICS 5 5 5 SAFETY FEATURES 5 5 6 OTHER CHARACTERISTICS 6 5 7 INDICATOR LIGHT 7 7 DIMENSION AND INSTALLATION 9 7 1 DIMENSIONS 9 7 2 INSTALLATION MET...

Page 6: ...8 9 3 1 Start Mode Instruction 18 9 3 2 Charging Interface Instruction 19 8 System Remote Upgrading Instruction 23 10 FAULT ALARM AND TREATMENT 24 10 1 FAULT AND RECOVERY 24 10 2 FAULT ALARM AND TREAT...

Page 7: ...waterproof dustproof and corrosion proof function and have environmental protection design with protection grade of IP 54 The product with modular design concept has integrate the vehicle connector h...

Page 8: ...t 24 Digital communication between a DC EV charging station and an electric vehicle for control of DC charging IEC 61851 21 2 2018 Electric vehicle conductive charging system Part 1 2 Requirements for...

Page 9: ...EV control system 4 Environmental Conditions No Item Technical targets Unit Remark Working Transportation Storage 1 Temperature 30 55 40 70 40 70 2 Humidity 5 95 5 95 Condensation free 3 Altitude 2500...

Page 10: ...0 480 3P N PE 5 AC output frequency range 45 65 Hz Rated frequency 50Hz 60Hz 6 AC output mode 7kW Single phase three wire L N PE 22kW Three phase five wire 3P N PE 5 3 Protection characteristics No It...

Page 11: ...immunity Level 3 8 Harmonic current emission limit test Grade A 9 Voltage fluctuation and scintillation test Grade A 10 Power terminal conduction disturbance test Grade A 11 Signal port conduct distu...

Page 12: ...difference module each with 5 times 8 20us impulse wave Maximum discharge current is 40kA Voltage protection level is under 1 8kV 5 6 Other characteristics No Item Technical requirements Unit Remark 1...

Page 13: ...protection film or anti oxidation treatment 10 Environmental Protection Meet requirements of 2011 65 EU no cadmium hydride and fluoride 5 7 Indicator light No Indicator light Standby Plugged In charg...

Page 14: ...Charging card management system Support Complete card making and issuing system with asynchronous settlement function Optional 4 Back office monitoring Support Optional 5 Remote upgrading function Sup...

Page 15: ...nstallation 7 1 Dimensions 1 The outlook of the EV charger is as follows Figure 7 1 1 Outlook of the EV charger Note The above figure shows the appearance of standard models Some customized models hav...

Page 16: ...imension and size of the EV charger is shown as figure 7 1 2 and chart 7 1 1 Figure 7 1 2 Dimension of the EV charger Chart 7 1 1 Dimension parameters Unit mm Length L Width W Height H EV charger 160...

Page 17: ...ical surface installed should be smooth and reliable The power line enters from the bottom of the charger side For safe and beautiful use of the charger the power line inletting hole shall be reserved...

Page 18: ...rger after sale service and maintenance shall be fully considered Note This installation method is for reference only The corresponding installation method shall be selected according to the actual si...

Page 19: ...allation 40 PVC pipes need to be embedded in advance on the substrate as shown in the picture above 7 2 3 Note This installation method is for reference only The corresponding installation method need...

Page 20: ...er supply users need to remove the baffle cover of the junction box on the side of the charger and connect the cables of recommended specifications in chart 7 2 3 L N PE in turn according to the conne...

Page 21: ...Pin Number identification and Function Definition Pin No Identification Rated Voltage and Rated Current Function Definition 1 L1 250V 10A 16A 32A AC power supply single phase 2 L2 480V 16A 32A 63A AC...

Page 22: ...e contact the manufacturer staff for help Please refer to relevant instruction when operate the charging equipments Pay attention to insertion and extraction force of the vehicle connector to avoid ov...

Page 23: ...Mode Selection Ensure that charger connected with vehicle correctly Charging completed By Card Swipe the same card for settlement auto full charge Start charging Plug in and charge Start charging End...

Page 24: ...ct the output and stop charging The green indicator is always on 5 For cars with electronic lock first needs to press the unlock button on the car to unlock the electronic lock After the retractable r...

Page 25: ...he plug could be extracted Otherwise the plug will not be able to pulled out 6 After charging finished disconnect the charger from the vehicle and place the plug back into the designated position 9 3...

Page 26: ...e 9 3 2 4 5 below During normal charging process the charger panel green indicator light flashes Figure 9 3 2 4 Plug and charge page Figure 9 3 2 5 Charging by card page 3 Charging Finished Page The c...

Page 27: ...ault and re plug in before recharging Note Different times of the indicator light flashes stands for different fault types please refer to item 10 2 for details Figure 9 3 2 8 under voltage fault page...

Page 28: ...th unauthorized card charger will automatically pop up card identification failed as shown in Figure 9 3 2 12 When the countdown is over the screen will jump back to the default interface The user can...

Page 29: ...ency stop alarm state and the screen will back to the default interface Figure 9 3 2 13 Emergency stop fault page 8 System Remote Upgrading Instruction In system remote upgrade process the charger wil...

Page 30: ...ing stop of charger may be required Fault code Fault name Flashing times of red indicator light n Treatment 11 Input under voltage 1 Check incoming voltage 12 Input overvoltage 2 Check incoming voltag...

Page 31: ...uations like severe vibration impact exposure to the sun and rain package dumping etc shall be avoided during the transportation process The loading and unloading operation shall also be paid enough a...

Page 32: ...er there is deformation and looseness Electrical and Controlling System Inspection Monthly Routine Inspection 1 Good connection between the charger and earth need to be ensured and clear marks need to...

Page 33: ...ty 5 Security measures must be well improved and insulation shoes must be worn during maintenance operation to avoid personal injury and electric shock NOTICE 1 The company will not be responsible for...

Page 34: ...hould not press the mechanical button on the charging plug head to avoid the failure of normal charging due to improper insertion of the plug Check whether the mechanical button on the charging plug w...

Page 35: ...switch inside the charger trips or not If tripping found flip the switch to close the air switch After closing the charger indicator light will be lit again 3 After opening the charger if air switch...

Page 36: ...Mindra Green energy LLP Address Prasham 102 Devraj Industrial Park Piplaj Pirana Rd Calico Mills Ahmedabad Gujarat 382405 TEL 9157502603 Email support mindrasolar com...

Reviews: