Unit:mm
We reserve the right to change the specification without prior notice.
PR-0246D 2021/11 Printing
9
6
15.5
22.5
20
20
30
30
37
21.8
Rated pressure range
Withstand pressure
Applicable fluid
k
gf/cm
2
bar
psi
Pressure
resolution
Ambient humidity range
Vibration
Shock
Temperature characteristic
Weight
MPa
A.
SPECIFICATIONS
TYPE
Battery
Battery life
Low-power indicator
Battery replaceable
Turn-on interval
Sampling rate
Repeatability
Display
Indicator accuracy
B.
ORDERING INFORMATION
F1 : R1/8", M5
F2 : NPT1/8", #10-32 UNF
F3 : G1/8"(BSPP), M5
F4 : R1/4", M5
F5 : NPT1/4", #10-32 UNF
F6 : G1/4”(BSPP), M5
Optional Parts
C.
PANEL DESCRIPTION
Battery Meter
Pressure Display
Setting Button
Pressure Unit
Display Section
D.
DIMENSIONS
E
.
BATTERY STATUS / INSTALLATION
F1~F3:Hex flat:12
F4~F6:Hex flat:14
F1 : R1/8", M5
F2 : NPT1/8", #10-32 UNF
F3 : G1/8"(BSPP), M5
F4 : R1/4", M5
F5 : NPT1/4", #10-32 UNF
F6 : G1/4”(BSPP), M5
1
4
7
8
MPa
MPa
6
"+"
"-"
1.5MPa
0.000 ~ 1.000MPa
Filtered air, incombustible and non-corrosive gases
0.01
0.01
0.1
0.001
Operation/Storage: 35 ~ 85% RH ( No condensation)
Total amplitude 1.5mm or 10G, 10Hz-55Hz-10Hz scan
for 1 minute, two hours each direction of X, Y and Z
100m/s
2
(10G), 3 times each in direction of X, Y and Z
Approx. 40g
Yes
Yes
2 Hz (2 times/sec.)
3 ½ digital, 7 segment LCD display ( Black )
±2% F.S. ±1 digit (ambient temperature: 25 ±3 °C)
Operation: 0 ~ 50 ºC, storage: -10 ~ 60 ºC
( No condensation or freezing)
±2% F.S. of detected pressure (25°C) at temp.
range of 0~50°C
Ambient temp. range
Enclosure
Environment
*1. When the pressure is -0.1MPa, LCD displays MPa.
*2. Air tube must be installed to maintain IP65. (See section K)
5
2
3
MPG-60
Series
For your safety, please read the following before using.
1
2
3
4
5
6
FOLLOW THE STEPS BELOW
●
Using a flat screwdriver size 1.4 ~ 3.0 mm insert into the back of the
pressure gage as pictured. (See figure )
●
Turn the screwdriver horizontally 90° to separate the case and the base.
Repeat this process again for the other side. (See figure )
● C
arefully remove the outer cover (See figure ), and follow the diagrams
below to replace battery and reassembly. Polarity must be observed,
incorrect battery installation will cause malfunction.
2
3
4
(Positive)
(Vacuum)
MPG-60V-
MPG-60P-
MPG-60VL-
MPG-60PL-
mmHg
CR 2032 lithium
IP
65
*2
Pressure Range
Pressure Port
V : Vacuum (10 ~ -101kPa)
P : Positive (-0.100 ~ 1.000MPa)
0 ~ -101kPa
-0.100 ~ 1.000MPa *1
10 ~ -101kPa
Display pressure range
300kPa
k
Pa
-
-
0.01
0.1
1
1
-
-
Display turn off after 60 sec.
(Vacuum)
(Positive)
psi bar mmHg kPa
psi bar kgf MPa
Port size
F1:R1/8”, M5; F2:NPT1/8”, #10-32 UNF; F3:G1/8”(BSPP), M5
F4:R1/4”, M5; F5:NPT1/4”, #10-32 UNF; F6:G1/4”(BSPP), M5
3 years
(5 times/day)
3 years
(5 times/day)
1 year
(5 times/day)
1 year
(5 times/day)
Pressure unit
psi, bar, kgf/cm
2
and MPa
u
ser selectable
psi, bar, mmHg and kPa
u
ser selectable
Back light
Yes
Yes
No
No
Back Light
Blank : Back light unavailable
L : Back light available
Do not use corrosive or flammable gas or liquid with this product.
Please use within the rated pressure range. Do not apply pressure
beyond recommended maximum withstand pressure, permanent
damage to the pressure gage may occur.
Do not drop, hit or allow excessive shock. Even if press
ure gage
body
appears undamaged, internal components may be broken and
can cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere
containing flammable or explosive gases.
Using filter can extend pressure gage’s service life.
MP-A5 : Mounting bracket (BT-5)
MP-A6 : Mounting bracket (BT-6)
MP-B2 : Panel adapter (PA-C)
MP-C2 : Panel a Front protective lid (PA-D)
±0.2% F.S. ±1digit
±
1
% F.S. ±1digit
M P G - 6 0 P L - F 1
Ø 2mm MAX