background image

Note :

When

 using a unit mmH

2

O, please multiply display value by 100.

Alternately displayed

Alternately displayed

Alternately displayed

Alternately displayed

(M)

(M)

(M)

(*1)

(*1)

(*1)

(*1)

(*

2)

(*

2)

(*

2)

(*

2)

Measure mode

(M)

(M)

Measure mode

Use the    or    button to set desired pressure unit.

初使設定模式

MODEL

MP30V/MP30C

mmHg

kPa 

kgf/cm

2

bar

psi

Use the    or    button to set OUT1 mode.
Output type

NO: normal open mode 
NC: normal close mode

初使設定模式

OUT1 mode setting

MPa

kgf/cm

2

bar

psi

MODEL

M

P30P

(M)

(M)

初使設定模式

(M)

2.5ms

24ms

192ms

768ms

初使設定模式

Response time setting 

Use the    or    button to select response time.

(M)

Pressure value setting : Auto/Manual

Use the    or    button to select auto/manual setting. 

(M)

Unit setting

NO Mode NC Mode

NO Mode NC Mode

Measure mode

Press(M) button for more than 3 seconds.

OUT2 mode setting

Use the    or    button to set OUT2 mode.
Output type

NO: normal open mode
NC: normal close mode

Measure mode

inHg

mmH

2

O

Manual setting 

mode

Auto setting 

mode

量測模 式

歸 零 設 定

量測 模式

壓力設定模式

Measure Mode

Zero Point Setting

Pressure Setting Mode

Setting zero point under 

atmospheric pressure

Output Mode

Unit 

Response Time

Auto/Manual

P_1 or n_1

P_2 or n_2

P_3 or n_3

P_4 or n_4

Initial Setting Mode

Measure Mode

kPa

kgf/cm

2

mmHg

inHg

bar

psi

MPa

From

To

1 kPa
1 MPa

1 Pa

1000.000

1000000

1

98066.5

133.32

6895

6.895

0.006895

0.07031

51.7157

1

0.06895

2.036074

703.07

0.2953

295.2998

0.0002953

0.101968
101.9689
101968.9

0.010000

10

0.00001

0.145038

145.038

0.000145038

7.500616
7500.616

0.00750062

0.010197

10.197

0.000010197

0.001000

1

0.000001

1

1000

0.001

100000.0

100.0000

0.100000

1.01972

750.062

14.5038

1

29.52998

28.95979

10000.20

0.980665

14.2233

735.559

1

0.0980665

98.0665

3386.388

9.80665

3.386388

0.00980

0.003386

-

0.034530
0.000099

25.40000

0.0735578

0.491141

0.00142

0.033863
0.000098

1

0.002895

345.324

1

0.039370

13.5954

0.0013332

0.019336

1

0.0013595

0.000133

0.13332

1 kgf/cm

2

1 mmHg
1 psi
1 bar
1 inHg
1 mmH

2

O

Pa

kPa

MPa

kgf/cm

2

mmHg

psi

bar

inHg

mmH

2

O

10196.89

mmH

2

O

CHANGE  PRESSURE UNIT TAG

SETTING STEPS

INITIAL SETTING MODE

PRESSURE SETTING MODE

The LED shows (P_*) at normal open 

mode and. (n_*) at normal close mode.
Pressure setting value is shown normally 

and will not lead to pressure sensor  

pause or stop working.
Change pressure value

Press    button, each press will increase 

one digit. Keep pressing the    button, the 

pressure value will keep increasing. 
Press    button , each press will decrease 

one digit. Keep pressing the    button, the 

pressure value will keep decreasing.

NOTE :

Calculation of  Setting value

P

2

(

n2

)

P

4

(

n4

)

=

B+ A-B

        

4

        

A=The max. 

pressure value under auto setting mode.

B=The min. 

pressure value under auto setting mode.

P

1

(

n

1

)

P

3

(

n

3

) =

A –

A-B

4

P

2

(

n

2

)

P

4

(

n

4

) =

B+ A-B

4

Auto setting mode

OUTPUT TYPE

The Max. value display mode

    Press      button 2 seconds to enter the max. value mode, pressure

    sensor will detect the max. value and keep display.

    Press      button 2 seconds to return to measure mode.

The Min. value display mode

    Press      button 2 seconds to enter the min. value mode, pressure 

    sensor will detect the min. value and keep display.

    Press      button 2 seconds to return to measure mode.

Zero point setting

    Press the      +      button at the same time until the "00" is shown.

    Release the button to end zero setting.

Unlcok mode

Lock mode

Press (M ) more than 5  seconds.

(M)

Select auto/manual setting mode during initial set-up.

Use    or    to select key lock/unlock mode.

Key lock mode can prevent operation mistakes.

*1.

*2.

Measure mode

Measure mode

ERROR CODE INSTRUCTION

ZERO POINT SETTING / THE MAX. &  MIN. DISPLAY MODE 

KEY LOCK/UNLOCK MODE

OUT2

OUT1

(M)

(M)

(M)

(*1)

(*3)

(*2)

Measure mode

(M)

(M)

Measure mode

(*3)

Prepare auto setting mode  

at OUT1 switch.
Under this mode, the device 

needs to be set repeatedly 

in order to reach the auto 

setting value.
Prepare auto setting mode  

at OUT2 switch.

NOTE :

*3.

*1.

*2.

In case of without need of OUT1  

pressure value setting, press        
           at the same time to enter 

(AP2)/(An2).
In case of without need of OUT2  

pressure value setting, press       
           at the same time to enter 

measure mode.
The LED show

AP*

at 

normal open mode and

An*

at normal close mode.

OUT2

OUT1

【NOTE :】When hysteresis mode setting is within 2 digits, if the input

                    and pre-set pressure is quite near, pressure sensor output  

                    might cause chattering.

Vacuum (MP30V)

Positive/

Compound 

(MP30P/MP30C)

Hysteresis Mode :

 

Output hysteresis value can be pre-set.

Normal open 

mode

 

Normal open 

mode

 

Normal open 

mode

 

Normal close 

mode

 

Vacuum (MP30V)

Positive/

Compound 

(MP30P/MP30C)

P_1

P_3

P_2

P_4

Positive Pressure

Vacuum Pressure

Positive Pressure

Vacuum Pressure

NOTE :

Hysteresis is fixed in 3 digits.  

                     Pressure value level setting : At least 6 digits.

Vacuum (MP30V)

Positive/

Compound 

(MP30P/MP30C)

Window comparator mode :

 

Within pressure setting range, pressure sensor output can be ON or OFF.

Vacuum (MP30V)

Positive/

Compound 

(MP30P/MP30C)

Positive Pressure

Vacuum Pressure

Positive Pressure

Normal open 

mode

 

Normal close 

mode

 

P_1

P_3

P_2

P_4

n_1

n_3

n_2

n_4

Vacuum Pressure

P_1

P_3

P_2

P_4

n_2

n_4

n_1

n_3

n_2

n_4

n_1

n_3

H

=

3 digits

P1(n1)>P2(n2)

P3(n3)>P4(n4)

P1(n1)<P2(n2)

P3(n3)<P4(n4)

Manual setting mode

Under this mode, the device 

needs to be set repeatedly 

in order to reach the auto 

setting value.

High Precision Digital Pressure  

MP30

When the pressure setting is not kPa or MPa, please remove the pressure unit tag and place the selected tag on the

indicated area of the faceplate to assure the pressure unit is not misemployed and that setting error does not occur.

Applied 

pressure error

System error

The applied pressure is excess the upper limit of pressure setting.

Adjust the pressure within applied 

pressure range.

Internal data error

Turn power off, and then restart. If error 

condition remains, please return to factory 

for inspection.

---

----

Error Name Error code

Error instruction

Troubleshooting

Excess load 

current error

Residual  

pressure error

Excess load current of 100 mA

OUT1
OUT2

Change input pressure to ambient 

pressure and perform zero reset again.

The applied pressure is excess the lower limit of pressure setting.

Internal system error

Internal data error

Internal system error

During zero reset, ambient pressure is over ±3% F.S.

Turn power off and check the cause of

over load current or lower the current

load under 100mA, then restart.

www.mindman.com.tw