5-11 PARAM_DEFAULTS
Description: Set the parameters to default values
Packet Format
Length Opcode Status Setting
type Checksum
0x04
0x25
Field Descriptions
Field Name
Format
Size
Description
Length
0x04
1 Byte
Length Field
Opcode
0x25
1 Byte
Identifies this opcode type.
Status
Bit 0: Identifies transmit status
Bit 6-1: Unused
Bit 7: Command source
1 Byte
Bit 0:
0=First time packet is sent
1= Subsequent transmission
Bit 7: always be 1(message is from the host)
All unused bits recommend to be set to 0.
Setting type
Default setting type
1 Byte
0-255.
0: Default setting 0 (Mindeo standard)
Checksum
2's complement sum of message
contents excluding checksum.
2 Bytes
Checksum of message.
For example: return all parameters to the factory default setting values.
Length
Opcode
Status
Setting type
Checksum
0x04
0x25
0x80
0x00
0xFF 0x57
Host Requirements
The host sends this command to reset the scanner’s parameter settings to the factory default values.
Scanner Requirements
Upon receiving this command, the scanner’s resets all parameters (except Scan mode) to the factory
default values. The behavior is the same as scanning factory defaults configuration barcode, see section
“
11 Return default parameters & firmware version
”
.