34
3-13 UPC-E
Read:
Format
System character “0” Data digits (6 digits) Check digit
Check digit verification:
The check digit is optional.
Check digit trans.:
By setting Enable, check digit will be transmitted.
Code ID setting:
Insertion group selection:
Refer to Insertion group selection of
Supplement digits:
Format
System character “0” Data digits (6 digits) Check digit Supplement digits 2 of 5
Truncation/Expansion:
Truncate leading zeros
- The leading
“0” digits of UPC-E data characters can be truncated when
the feature is enabled.
Ex
ample: Barcode “00123457”,
Output: “123457”.
Expand to EAN-13
- It extends to 13-digits with a
“0” leading digit when the feature is enabled.
Example: Barcode “00123457”,
Output: “0001234000057”.
Expand to UPC-A
- It extends to 12-digits when the feature is set to be enabled.
Example: Barcode “00123457”,
Output: “001234000057”.
Truncate system character
- The system character
“0” of UPC-E data can be truncated when the
feature is enabled.
Example: Barcode “00123457”,
Output: “0123457”.
Add country code
- The country code (
“0” for USA) can be added when the feature is enabled.
Example: Barcode “00123457”,
Output: “000123457”.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Check digit verification
Disable
00
Enable
01*
*
Check digit trans.
Disable
00
Enable
01*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<D>*
*
Insert group selection
00-66
00-66
00*
*