background image

86 

 

Multiple-scan setting 

Single-scan setting 

Option bar code 

Option 

Alpha. entry 

Prefix transmission 

 

Disable 

00* 

Enable 

01 

 

Suffix transmission 

 

Disable 

00 

 

Enable 

01* 

Code name transmission 

 

Disable 

00* 

Enable 

01 

 

Preamble transmission 

 

Disable 

00* 

Enable 

01 

 

Postamble transmission 

 

Disable 

00* 

Enable 

01 

 

Code ID transmission 

 

Disable 

00* 

Proprietary ID 

01 

 

AIM ID 

02 

 

Code length transmission 

 

Disable 

00* 

Enable 

01 

 

Case conversion 

 

Disable 

00* 

Upper (data only) 

01 

 

Lower (data only) 

02 

 

Upper (whole string) 

03 

 

Lower (whole string) 

04 

 

FN1 substitution transmission 

Disable 

00* 

Summary of Contents for CS7290-BT

Page 1: ...CS7290 BT Cordless Image Scanner User Manual Version CS7290 BT_UM_EN_V1 0 3...

Page 2: ......

Page 3: ...ich can damage the scanner interrupt program execution corrupt memory contents or otherwise interfere with proper operation 7 Use a blunt object to operate the stroke keys Use of a sharp pointed objec...

Page 4: ...tery by incinerating it or otherwise expose it to heat Doing so creates the danger of battery heat emission explosion and fire 5 Never allow the positive and negative terminals of the battery to becom...

Page 5: ...he laser beam Doing so can cause serious eye damage Lithium ion battery 1 Do not put a battery in microwave ovens or pressure cookers Doing so may cause the battery to overheat explode or burst into f...

Page 6: ...pull on the power cord Doing so creates the danger of fire and electrical shock 4 Use only the AC DC adaptor and charger specified in this manual Use of other AC DC adaptor models or chargers creates...

Page 7: ...unlight or any other very hot area Doing so creates the danger of heat emission and fire as well as deterioration of battery performance and shortening of its service life 2 Do not use the battery in...

Page 8: ...o do so can result in damage to the power cord caused by pulling it which creates the danger of fire and electrical shock 5 Be sure to unplug the power cord from the wall outlet before cleaning the Ba...

Page 9: ...e 1 Single parameter setting by scanning 1D barcodes 9 3 2 Example 2 Multiple parameter setting by scanning a QR code barcode 10 3 3 Wireless communication setting 11 3 3 1 Bluetooth mode 11 3 3 2 Blu...

Page 10: ...S1 DataBar GS1 DataBar Truncated 73 3 33 GS1 DataBar Limited 74 3 34 GS1 DataBar Expanded 75 3 35 PDF417 76 3 36 MicroPDF417 77 3 37 QR Code 78 3 38 Data Matrix 79 3 39 Aztec Code 80 3 40 G1 G4 C1 C2...

Page 11: ...een LED Wavelength 525nm Working Time 20 hours 1 scan per 5 seconds Image Size 1280 1024 pixels Field of View HD Horizontal 40 vertical 34 XD Horizontal 33 vertical 28 Scanning Angle 70 75 360 Skew Pi...

Page 12: ...to concrete Note Test condition temperature at 27 C sunny day and visibility of 5 kilometers Natural surroundings significantly affect the communication distance in practice The distance drops quickly...

Page 13: ...f 5 6 X Im Codabar 4 N Fm Code 128 1 K Cm UCC EAN 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im GS1 DataBar 16 2 R em GS1 DataBar Trun...

Page 14: ...Power 5V 2 3 3V for interface auto selection purpose Ground for interface auto selection purpose 3 3V for interface auto selection purpose 3 Ground Ground Ground 4 3 3V for interface auto selection p...

Page 15: ...5 2 2 Dimensions...

Page 16: ...press 3 seconds to turn on Beeper Successful decoding indicator Green LED Communication fail indicator Red LED Charging indicator Red Green LED Figure 2 3 Cradle Power indicator Blue LED Communicatio...

Page 17: ...turned on when the charging is in process When the charging process completes the Red LED is turned off and the Green LED is turned on 2 Charging time 6 hours for fully charged 3 You can charge the b...

Page 18: ...2 Windows gives message on new hardware found USB HID input device found then driver will be installed on request 3 After successfully installing the new hardware message will be given hardware insta...

Page 19: ...riate Single scan setting e g 0101D00 according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the Option barcode ba...

Page 20: ...r string with various length of 2 4 or other values Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03 8002H0...

Page 21: ...nner connects to the PC host via Bluetooth and behaves like there is a serial connection BLE The scanner connects to the PC host via Bluetooth and behaves like there is a serial connection Cradle The...

Page 22: ...canner supports different national keyboard layouts Inter character delay This delay is inserted after each data character transmitted By selecting the user can change the output speed of the scanner...

Page 23: ...tion barcode Option Alpha entry Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Thai 13 Hunga...

Page 24: ...will attempt to connect to the base at the same time the handheld terminal will make a beep beep beep sound If the connection is successful the handheld terminal can be used directly If the connection...

Page 25: ...0 9 a A z Z For example scan below setting barcode BTN 1234Md the Bluetooth will be named as 1234Md If the Bluetooth name is successful changed the beeper will have three beeps Bluetooth name display...

Page 26: ...tor flashes 1 time every 1 second When in working mode low battery indicator the buzzer beeps 4 times every 10 seconds and the blue LED indicator flashes 4 times When in standby or working mode Power...

Page 27: ...17 Multiple scan setting Single scan setting Option barcode Option Alpha entry 2 hours 05 3 hours 06 4 hours 07 Low battery indicator Disable 00 Enable 01...

Page 28: ...tically after successful sending If you want to output the total number of barcodes scanned when in Standard batch Mode scan BDN Standard batch 2 he handheld unit starts storing barcode data after EBM...

Page 29: ...ltiple scan setting Single scan setting Option bar code Option Alpha entry Batch data mode Disable 00 Out of range batch 01 Standard batch 1 02 Standard batch 2 03 Send batch data Total Records Clear...

Page 30: ...PC during power on Inter character delay This delay is inserted after each data character transmitted Inter byte delay This delay is inserted after each byte transmitted Normally a character is compri...

Page 31: ...ple Mac compatibles 01 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Character encoding sys...

Page 32: ...lay after compound key 0 ms 00 10 ms 01 20 ms 02 40 ms 03 80 ms 04 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 Power on simulation Disable 00 Enable 01 Inter character delay 0 ms 00...

Page 33: ...23 Multiple scan setting Single scan setting Option bar code Option Alpha entry Caps Lock reversion Disable 00 Enable 01 Caps Lock override Disable 00 Enable 01...

Page 34: ...the scanner receives an XON character ACK NAK After transmitting data the scanner expects either an ACK acknowledge or NAK not acknowledge response from the host When a NAK is received the scanner tra...

Page 35: ...ar code Option Alpha entry 80 ms 05 Response delay 00 99 100 ms 00 99 00 Baud rate 300 00 600 01 1200 02 2400 03 4800 04 9600 05 19200 06 38400 07 57600 08 115200 09 Parity None 00 Odd 01 Even 02 Data...

Page 36: ...pports different national keyboard layouts Inter character delay This delay is inserted after each data character transmitted By selecting the user can change the output speed of the scanner to match...

Page 37: ...HID keyboard 00 HID keyboard for Apple Mac 01 USB virtual COM 02 Support OPOS JPOS HID 04 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese...

Page 38: ...r delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 GBK 03 BIGS 04 TAIBUN 05 USB function code Output 0x00 0x1F characters 00 Outp...

Page 39: ...29 Multiple scan setting Single scan setting Option bar code Option Alpha entry Key value transmission mode Discontinuous transmission 00 Continuous transmission 01...

Page 40: ...er will start operating if any nearby object has been detected The scanner stops scanning when no code is successful decoded after the Stand by duration elapsed Once the scanner stops scanning the pre...

Page 41: ...nly i e in ASCII from 20H to 7EH Alphanumeric character only If this option is selected the scanner will output the alphanumeric characters only i e A Z a z 0 9 Decoder optimization If it is enabled t...

Page 42: ...04 Auto detection Good read on 06 Auto detection Good read off 07 Working mode of Auto detection In cradle 00 Always ON 01 Standby duration 4 seconds 00 8 seconds 01 16 seconds 02 24 seconds 03 30 se...

Page 43: ...2D symbol 00 FF16 50 ms 00 FF16 00 08 Double confirm 00 09 00 none 00 09 00 Global max code length for 1D symbol 04 99 04 99 99 Global min code length for 1D symbol 01 99 01 99 04 Global G1 G4 string...

Page 44: ...01 Data output delay in continue scan mode 00 99 100 ms FF Never 00 FF16 00 Character encoding system ASCII 00 UTF 8 01 Windows 1251 02 Simplified Chinese 03 Traditional Chinese 04 Windows 1250 05 KO...

Page 45: ...ach successful reading the scanner will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favor...

Page 46: ...entry Power on alert Disable 00 Enable 01 LED indication Disable 00 Enable 01 Beeper indication Disable 00 Enable 01 Beep tone duration 01 09 10 ms 01 09 10 Volume of beeper Low 00 Middle 01 High 02...

Page 47: ...mination Holding time of aiming light on After the scanner finishes the scanning action release the key successfully read the code the aiming light will remain on until the holding time of aiming ligh...

Page 48: ...ng 02 On when reading 03 Decode aiming pattern Always Off 00 Always On 01 On before reading 02 On when reading 03 Level of decode illumination Low 01 Middle 02 High 03 Holding time of aiming light on...

Page 49: ...Multiple scan setting Single scan setting Option barcode Option Alpha entry 1D symbols read Follow respective 1D symbol setting 00 All 1D Disable 01 All 1D Enable 02 2D symbols read Follow respective...

Page 50: ...can read 2D symbols in DPM Direct Park Marking format Some barcodes in DPM format are shown below Mobile screen read By setting enable the scanner can read barcodes on a mobile screen better However t...

Page 51: ...41 Multiple scan setting Single scan setting Option bar code Option Alpha entry DPM format read Disable 00 Enable 01 Mobile screen read Disable 00 Enable 01...

Page 52: ...r to Global insertion group selection of 3 9 Handheld scan some global settings Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters Format System character Data digit...

Page 53: ...1 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Only with Supp...

Page 54: ...nsertion group selection of 3 14 UPC A Supplement digits Format System character 0 Data digits 6 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros Refer to Trunca...

Page 55: ...1 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Only with Supp...

Page 56: ...tting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Supplement digits Format System character 1 Data digits 5 digits Check digit Supplement digits 2 or 5 Tru...

Page 57: ...e 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 O...

Page 58: ...to Insertion group selection of 3 14 UPC A Supplement digits Format Data digits 12 digits Check digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number or Bookl...

Page 59: ...Enable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 d...

Page 60: ...e data digits Check digit trans By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of...

Page 61: ...ation Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5...

Page 62: ...ength barcode decoded Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Start End transmission The start and end charact...

Page 63: ...le 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format S...

Page 64: ...ng Single scan setting Option bar code Option Alpha entry Enable 01 Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 Start End transmissio...

Page 65: ...are two optional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit transmission By setting Enable check digit will be transmi...

Page 66: ...ha entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code I...

Page 67: ...Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 E...

Page 68: ...Min code length of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multiple scan setting Single scan sett...

Page 69: ...fer to Insertion group selection of 3 14 UPC A Start End type Codabar has four pairs of Start End pattern you may select one pair to match your application Start End transmission Refer to Start End tr...

Page 70: ...tting Option bar code Option Alpha entry Insert group selection 00 66 00 66 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00 Enable 01 Start End...

Page 71: ...ansmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group sel...

Page 72: ...Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inse...

Page 73: ...ata digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14...

Page 74: ...Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inse...

Page 75: ...th of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multiple scan setting Single scan setting Option ba...

Page 76: ...in code length of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multiple scan setting Single scan setti...

Page 77: ...e 11 of all data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to M...

Page 78: ...ad Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 9...

Page 79: ...od 11 10 The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmi...

Page 80: ...Disable 00 Enable 01 Check digit verification Disable 00 1 digit mod 10 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00...

Page 81: ...Max Min code length Refer to Max Min code length of 3 19 Code 39 Code ID setting Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multi...

Page 82: ...ng Refer to Code ID setting of 3 14 UPC A Insertion group selection Refer to Insertion group selection of 3 14 UPC A Multiple scan setting Single scan setting Option bar code Option Alpha entry Read D...

Page 83: ...UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit has the...

Page 84: ...nsertion group selection of 3 14 UPC A Conversion Refer to Conversion of 3 32 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disabl...

Page 85: ...A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Di...

Page 86: ...76 3 35 PDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01...

Page 87: ...77 3 36 MicroPDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01...

Page 88: ...78 3 37 QR Code Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01...

Page 89: ...79 3 38 Data Matrix Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01...

Page 90: ...80 3 39 Aztec Code Read Format Data characters variable Multiple scan setting Single scan setting Option bar code Option Alpha entry Read Disable 00 Enable 01...

Page 91: ...dd a symbol of as a prefix for all symbols Steps 1 Scan the option barcode of Prefix string setting 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the last page 4 Sca...

Page 92: ...ed character The C1 and C2 replacement are applied simultaneously Example Replace all the A character in a data string to be B character Original code data 1 2 3 A 5 A Output code data 1 2 3 B 5 B Ste...

Page 93: ...ert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert G3 string setting 0 22 characters 00 FF16 None 00 Insert G4 string setting 0 22 ch...

Page 94: ...insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement Multiple scan set...

Page 95: ...e transmitted before the code data when Enable is selected The length is represented by a number with two digits Case conversion The characters within code data or the whole output string can be set i...

Page 96: ...ansmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 Code length transmiss...

Page 97: ...Option bar code Option Alpha entry Enable 01 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters only All 99 01 99 Transmit t...

Page 98: ...Test barcode symbols UPC A UPC E UPC E1 Default setting Read disable EAN 8 EAN 13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Default setting Read disable Matrix 2 of 5 Co...

Page 99: ...Code 11 Default setting Read disable MSI Plessey Default setting Read disable UK Plessey Default setting Read disable ISBN ISSN China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 Da...

Page 100: ...90 PDF417 12 890ab xyz MicroPDF417 Default setting Read disable 0239 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo Aztec Code Default setting Read disable 12345678901234567890...

Page 101: ...ning accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not spray water or other...

Page 102: ...8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only...

Page 103: ...If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select Code128 then select...

Page 104: ...lt setting WARNING If you wish to return all parameters of the cradle including radio communication setting to default setting please scan the barcode above Some parameters of handheld unit return to...

Page 105: ...the handheld unit again please keep the trigger key being pressing for seconds If you want to turn off the handheld unit via trigger key please press and hold the trigger key after the laser beam turn...

Page 106: ...barcode above Cradle Bluetooth version display If you wish to display the Bluetooth version of the cradle please scan the barcode above Handheld unit Bluetooth version display If you wish to display t...

Page 107: ...97 10 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Reviews: