Section II
Section II provides all of the necessary information for installing the FR-03 foot rest ledge into
an area that does not provide wood blocking.
DISCLAIMER NOTICE: If the prescribed method of installation is not followed
precisely, the foot rest ledge may detach from the wall and cause damage to the
panels and the walls. If the foot rest ledge detaches, physical injury to the
occupant of the shower may occur. Mincey Marble will not be liable for any
damages to persons or property because of incorrect installation.
In preparation, before installing this foot rest ledge, you will need to have
completed the installation of the panel system and sealed the seams of the
shower panels behind where the foot rest ledge is to be installed with 100%
silicone.
Installing the Foot Rest Ledge without wood blocking:
If the wood blocking
has not been installed
,
WingIt model # MAW35-SD
fasteners
should be ordered to install the foot rest ledge. See drawing (A). They can be ordered
direct from Mincey Marble.
Drawing A:
Tools /Materials Required:
1. Drill, preferably corded, for drilling holes
2.
3/16” masonry drill bit
3. Measuring tape
4. Pencil
5. 100% silicone for marble to marble seams (color matched for the marble)
6. Clean, dry cloths to clean both the foot rest ledge and wall
7. White silicone to be used for adhering the foot rest ledge to the wall