Mincey Marble Manufacturing FR-03 Installation Instructions Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Installation Instructions for Mincey Marble Manufacturing’s  

Wall Mount Foot Rest Ledge 

For use with the Confetti Tile Pattern Contemporary Panel System 

- FairField Inn & Suites by Marriott -  

 

 

Product number: FR-03 

 
 

DISCLAIMER NOTICE: If the prescribed method of installation is not followed 
precisely, the foot rest may detach from the wall and cause damage to the panels 
and the walls. If the foot rest ledge detaches, physical injury to the occupant of 
the shower may occur. Mincey Marble will not be liable for any damages to 
persons or property because of incorrect installation.  

 
 

These instructions have been written for Mincey Marble

’s FR-03 cast marble wall 

mount foot rest ledge. If you have a different product than shown, please call us 

for instructions for the product you received.  

 
 
 
 

 

 

 

                                                                      

Mincey Marble Mfg., Inc. 

4321 Browns Bridge Road 
Gainesville, GA  30504 
Ph:  800.533.1806 
Fx:  770.531.0935 

www.minceymarble.com

 

 

Summary of Contents for FR-03

Page 1: ...e to the panels and the walls If the foot rest ledge detaches physical injury to the occupant of the shower may occur Mincey Marble will not be liable for any damages to persons or property because of incorrect installation These instructions have been written for Mincey Marble s FR 03 cast marble wall mount foot rest ledge If you have a different product than shown please call us for instructions...

Page 2: ...ght angle or ratcheting right angle screwdriver will make the installation easier 9 Three 10 x 3 Stainless Steel Truss Head Sheet Metal Screws provided by Mincey Marble to attach foot rest ledge to required wood blocking supplied by others These screws will be packaged with the foot rest ledge PLEASE NOTE There should be a minimum 2 x 6 pressure treated wood blocking in the wall behind the substra...

Page 3: ... blocking in order to avoid damaging the cast marble panels The integral support of the foot rest ledge has a short side and a long side The short side of the foot rest ledge will be installed onto the back wall and the long side will be on the end wall of the enclosure Installing the Foot Rest Ledge with wood blocking 1 Measure the locations of the slots on the back of the foot rest ledge and tra...

Page 4: ...o the wall ILLUSTRATION 3 4 Apply 100 silicone to the entire back of the foot rest ledge using a minimum bead of silicone This step cannot be skipped or avoided as the silicone adhesive is a necessary product in the installation of the foot rest ledge as the truss head screws are not designed to be a stand alone installation product 5 Slide the foot rest ledge over the Truss Head Screws and press ...

Page 5: ...dge to the cast marble panels This seal should go around the entire perimeter of the foot rest ledge even under the bottom of the foot rest ledge DISCLAIMER NOTICE If the prescribed method of installation is not followed precisely the foot rest ledge may detach from the wall and cause damage to the panels and the walls If the foot rest ledge detaches physical injury to the occupant of the shower m...

Page 6: ...t rest ledge you will need to have completed the installation of the panel system and sealed the seams of the shower panels behind where the foot rest ledge is to be installed with 100 silicone Installing the Foot Rest Ledge without wood blocking If the wood blocking has not been installed WingIt model MAW35 SD fasteners should be ordered to install the foot rest ledge See drawing A They can be or...

Page 7: ... rest ledge once installed must be even with the top of the 1 1 2 band of the cast marble panels so the location of the drilled holes is critical in order to maintain alignment of the foot rest ledge to this band See illustration 2 ILLUSTRATION 1 ILLUSTRATION 2 2 Use stud finders to locate studs You must avoid studs in order for the WingIt to work When you are not positive of where the stud is dri...

Page 8: ...n put onto the wall ILLUSTRATION 3 5 Apply 100 silicone to the entire back of the foot rest ledge using a minimum bead of silicone This step cannot be skipped or avoided as the silicone adhesive is a necessary product in the installation of the foot rest ledge as the truss head screws are not designed to be a stand alone installation product 6 Slide the foot rest ledge over the Truss Head Screws a...

Page 9: ... silicone to cure before weight is applied to the foot rest ledge No weight should be applied to the foot rest ledge during this 48 hour period If the foot rest ledge is used before the allotted 48 hours all warranties will be void DISCLAIMER NOTICE If the prescribed method of installation is not followed precisely the foot rest ledge may detach from the wall and cause damage to the panels and the...