Programming Instructions
18
Programming Mode
Programming can be done before the DLC is installed, or before
it is connected to the speed controller, or after the entire system is
set up. Usually, it is more convenient to program the DLC before
it is connected to the speed controller, because the motor will not
then be running.
Press the front panel push-button marked "E" (ENTER) at the
same time that you power the DLC unit and it will be put into its
Programming Mode. If the DLC is already powered up, you must
interrupt power and hold in the ENTER push-button while
restoring AC power.
DLC programming parameters
Four parameters must be programmed into the Digi-Lok®
Converter. Three parameters can be programmed without running
the motor. The Speed Scaling Factor correlates the digital speed
set at the DLC with the desired speed at the feedback shaft. The
Display Scaling Factor correlates the numerical value displayed
by the DLC with the rpm at the feedback shaft. The Decimal
Point Location Number fixes the position of a decimal point
within the DLC display.