5.1.12 ACTION TEST
Function
Checks the operation of movable parts alone of the machine.
List of test items
Item
Description
VACUUM FAN
Description: Operation test of vacuum fan motor.
Set value: L.L, LOW, MID, HIGH, OFF
DRY FAN &
DEOD. FAN
Description: Optional operation test of dry/exhaust fan motor. (option)
Set value: ON, OFF
Y-CUTTER
Description: Operation test of media cutter.
Set value: UP, DOWN
[FUNCTION]: Sets operation interval of Y-cutter.
[
], [
]: Sets operation interval.
Set value: 0 – 7200 sec (unit: 1 sec)
[ENTER]: Repeats UP and Down at the set interval.
Number count is displayed during the execution.
LED POINTER
Description: Operation test of LED pointer.
Set value: ON, OFF
HDC FAN
Description: Operation test of HDC fan.
Set value: ON, OFF
MAINTENANCE MANUAL > Test Items > Test Function > ACTION TEST
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0