![MIMAKI JV3 S SERIES Operation Manual Download Page 100](http://html.mh-extra.com/html/mimaki/jv3-s-series/jv3-s-series_operation-manual_1800250100.webp)
- 5.16 -
When not in use the plotter over the long term [CUSTODYwash]
When not in use the plotter over a week, perform “CUSTODYwash” function to clean the head
nozzle and ink discharge way.
After performing the function, store the plotter.
Cleaning tools
•
C
leaning solution
RS(SPC-0336),
Pipette
•
Glove, Goggle
STEP
1.
Push the [FUNCTION] key.
2.
Push the [ ] and [ ] key until the display gives
the indication [MAINTENANCE].
3.
Push the [ENTER] key.
[STATION] is displayed.
4.
Push the [ ] and [ ] key until the display gives
the indication [CUSTODYwash].
5.
Push the [ENTER] key.
The carriage moves to the platen.
6.
Open the front cover.
7.
Fill the cap with the cleaning fluid using a
pipette.
8.
Close the front cover, and push the [ENTER]
key.
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
< ent >
STATION
MENT : CUSTODYwash
STATION
COMPLETED
: ent
STATION
LEAVING
: 1 min