background image

3

SERVICE

‡+DYH \RXU SRZHU WRRO VHUYLFHG E\ D TXDOL¿HG

repair person using only identical replacement 

parts. 

This will ensure that the safety of the power 

WRROLVPDLQWDLQHG

‡1HYHUVHUYLFHGDPDJHGEDWWHU\SDFNV

Service 

of battery packs should only be performed by the 

PDQXIDFWXUHURUDXWKRUL]HGVHUYLFHSURYLGHUV

SPECIFIC SAFETY RULES FOR 

BACKPACK SPRAYER

WARNING

5LVNRI¿UHRUH[SORVLRQ'RQRW

VSUD\ÀDPPDEOHOLTXLGVVXFKDV

gasoline, solvents, or gas producing chemicals. 

'RQRWXVHWRRODURXQGVSDUNÀDPHRUVPRNH

Chemical may ignite. 

• Use the correct tank for your application. These 

SURGXFWVDUHVXLWDEOHIRUSHVWLFLGHDSSOLFDWLRQV

VXFKDVLQVHFWLFLGHVIXQJLFLGHVRUKHUELFLGHV

fertilizers, concrete applications (such as seal-

DQWVFXULQJFRPSRXQGVDQGIRUPRLODQGZDWHU

supply applications, when used in accordance 

with these instructions and those supplied with 

the chemicals. 

‡'RQRWXVHEOHDFKFDXVWLFDONDOLVHOIKHDWLQJ

RUFRUURVLYHDFLGOLTXLGVLQWKLVVSUD\HU'RQRW

SRXUKRWRUERLOLQJOLTXLGVLQWRWKHWDQN7KHVH

can corrode metal parts or weaken the tank and 

hose.  

‡7RUHGXFHWKHULVNRI¿UHSHUVRQDOLQMXU\DQG

product  damage  due  to  a  short  circuit,  never 

LPPHUVH\RXUWRROEDWWHU\SDFNRUFKDUJHULQ

ÀXLGRUDOORZDÀXLGWRÀRZLQVLGHWKHP'RQRW

SODFHRUVWRUHWRROZKHUHLWFDQIDOORUEHSXOOHG

LQWRDWXERUVLQN&RUURVLYHRUFRQGXFWLYHÀXLGV

such as seawater, certain industrial chemicals, 

DQGEOHDFKRUEOHDFKFRQWDLQLQJSURGXFWVHWF

can cause a short circuit. 

• Electric  shock  hazard.  Never  spray  toward 

electrical outlets.

‡6SUD\ DUHD PXVW EH ZHOO YHQWLODWHG WR DYRLG

KD]DUGRXVIXPHVEXLOGXS

‡$YRLG VSUD\LQJ RQ ZLQG\ GD\V 6SUD\ FDQ EH

EORZQRQWRSHRSOHSODQWVRUREMHFWVWKDWVKRXOG

QRWEHVSUD\HG

• Do not store chemicals in the tank. Chemicals 

can degrade seals and hoses. Drain and clean 

after each use.

‡5HPRYHJORYHVEHIRUHKDQGOLQJEDWWHU\SDFNV

Chemicals are harmful to plastics.

• Maintain  your  power  tool.  Thoroughly  inspect   

inside  and  outside  and  examine  all  compo-

QHQWVEHIRUHHDFKXVH&KHFNIRUFUDFNHGDQG

deteriorated hoses, leaks, clogged nozzles, and 

missing or damaged parts. If damaged, have the 

SRZHUWRROUHSDLUHGEHIRUHXVH

Many accidents 

DUHFDXVHGE\SRRUO\PDLQWDLQHGSRZHUWRROV

• 

$OZD\VXQSOXJWKHFKDUJHUDQGUHPRYHWKHEDWWHU\

SDFNIURPWKHFKDUJHURUWRROEHIRUHSHUIRUPLQJ

any maintenance, storing, or draining the tool. 

1HYHU GLVDVVHPEOH WKH WRRO EDWWHU\ SDFN RU

charger. Contact a MILWAUKEE service facility 

for ALL repairs.

• Do not eat or smoke while handling or operating 

the tool. After use, wash with hot, soapy water 

to help reduce the risk of health hazards due to 

exposure to chemicals.

‡$OZD\VXVHFRPPRQVHQVHDQGEHFDXWLRXVZKHQ

using  tools. 

It  is  not  possible  to  anticipate  every 

VLWXDWLRQ WKDW FRXOG UHVXOW LQ D GDQJHURXV RXWFRPH

Do not use this tool if you do not understand these 

operating instructions or you feel the work is beyond 

your capability; contact Milwaukee Tool or a trained 

SURIHVVLRQDOIRUDGGLWLRQDOLQIRUPDWLRQRUWUDLQLQJ

 

'RQRWXVHWKHEDWWHU\FRPSDUWPHQWIRUVWRUDJH

 

0DLQWDLQ ODEHOV DQG QDPHSODWHV

These  carry 

LPSRUWDQW LQIRUPDWLRQ ,I XQUHDGDEOH RU PLVVLQJ

contact  a  MILWAUKEE  service  facility  for  a  free 

UHSODFHPHQW

• 

WARNING

Some dust created by power sanding, 

sawing, grinding, drilling, and other 

construction activities contains chemicals known to 

cause  cancer,  birth  defects  or  other  reproductive 

KDUP6RPHH[DPSOHVRIWKHVHFKHPLFDOVDUH

• lead from lead-based paint

• crystalline silica from bricks and cement and other 

masonry products, and

• arsenic  and  chromium  from  chemically-treated 

OXPEHU

 Your risk from these exposures varies, depending on 

KRZRIWHQ\RXGRWKLVW\SHRIZRUN7RUHGXFH\RXU

H[SRVXUHWRWKHVHFKHPLFDOVZRUNLQDZHOOYHQWLODWHG

area, and work with approved safety equipment, such 

as those dust masks that are specially designed to 

¿OWHURXWPLFURVFRSLFSDUWLFOHV

SAVE THESE  

INSTRUCTIONS

SYMBOLOGY

 

  

Volts

 

 

Direct Current

 

 

Read operator's manual

 

PPE

 

Wear personal protective equipment    

 

 

(PPE) according to the chemical 

 

PDQXIDFWXUHUVLQVWUXFWLRQV

 

 

Wear eye protection

 

 

Wear gloves

 

'RQRWVSUD\ÀDPPDEOHOLTXLGV

 

C

US

 8//LVWLQJIRU&DQDGDDQG86

SPECIFICATIONS

Cat. No. ..................................................... 2820-20 

Volts

18 DC

Battery Type

M18™

Charger Type

M18™

Recommended Ambient 

   Operating Temperature

32°F to 125°F

Tank Capacity

*DO/

Flow Rate

 WR*30

Full Weight

55 lbs

Tank Only (Pesticide)

49-16-28PS

Tank Only (Concrete)

49-16-28CS

Tank Only (Water)

49-16-28WS

Summary of Contents for M18 SWITCH TANK

Page 1: ...ISATEUR POUR VERSAGE D EAU BASE MOTORIZADA SWITCH TANK M18 CONJUNTO DE TANQUE ROCIADOR CONJUNTO DE TANQUE ROCIADOR DE CONCRETO CONJUNTO DE TANQUE DE SUMINISTRO DE AGUA OPERATOR S MANUAL MANUEL de L UT...

Page 2: ...application The correct power tool ZLOO GR WKH MRE EHWWHU DQG VDIHU DW WKH UDWH IRU ZKLFK LW ZDV GHVLJQHG Do not use the power tool if the switch does not WXUQ LW RQ DQG R Any power tool that cannot b...

Page 3: ...damaged have the SRZHU WRRO UHSDLUHG EHIRUH XVH Many accidents DUH FDXVHG E SRRUO PDLQWDLQHG SRZHU WRROV OZD V XQSOXJ WKH FKDUJHU DQG UHPRYH WKH EDWWHU SDFN IURP WKH FKDUJHU RU WRRO EHIRUH SHUIRUPLQJ...

Page 4: ...ne of the wand storage loca WLRQV Connecting the Nozzles DW 1R 36 6 6HOHFW DQG VFUHZ RQ QR OH E MRE W SH KHQ XVLQJ WKH DGMXVWDEOH QR OH DGMXVW VSUD SDWWHUQ DV GHVLUHG E WLJKWHQLQJ ORRVHQLQJ WKH QR OH...

Page 5: ...oose the sprayer may slide around on your back making it XQFRPIRUWDEOH WR ZHDU H DZDUH WDQN FRQWHQWV PD VKLIW GXULQJ XVH DQG PRYHPHQW VXFK DV WZLVWLQJ RU EHQGLQJ RYHU OPERATION Adjusting the Flow Rate...

Page 6: ...VHUYLFH IDFLOLW IRU LQVSHFWLRQ If the tool does not start or operate at full power with a fully charged battery pack clean the contacts on WKH EDWWHU SDFN I WKH WRRO VWLOO GRHV QRW ZRUN SURS erly retu...

Page 7: ...ite Radios M12 Power Port M18 Power Source Jobsite Fan and Trade Titan Industrial Work Carts is one 1 year IURP WKH GDWH RI SXUFKDVH 7KH ZDUUDQW SHULRG IRU WKH UDLQ OHDQLQJ DEOHV LV WZR HDUV IURP WKH...

Reviews: