background image

4

Installing/Removing the Accessories

To 

install

 the nozzles, line up the tabs on the nozzle 

with the notches on the tube. Slide the nozzle onto 

the tube until it snaps in place. Pull on the nozzle to 

ensure it is secure. To remove, press the tabs in and 

pull away from the tool. 

Fuel Gauge

Use the Fuel Gauge to determine the lowest battery 

pack's remaining run time. When less than 10% of 

times. When the battery reaches 0% charge, 1 light 

-

tery packs.

If the Fuel Gauge doesn't appear to be working, 

place the battery pack on the charger and charge 

as needed. 

Immediately after using the battery pack, the Fuel 

Gauge may display a lower charge than it will if 

checked a few minutes later. The battery cells "re-

cover" some of their charge after resting.

Fuel Gauge 

Lights

Diagnosis

Solution

Solid

Lights 1 - 4 

run time

Remaining Continue 

working

1 Light, 

Less than 

10% run time 

left

Prepare to charge 

pack

1 Light, 

discharge

End of 

Charge pack

SPECIFICATIONS

Cat. No. ................................................. M18 F2BL

Volts............................................................ 36V DC

Battery Type .................................................

Charger Type................................................

No Load RPM ...............................................16,750

Sound Pressure Level........................................ 83.0 dB(A)

Recommended Ambient 

ASSEMBLY

   Operating Temperature .................. -17°C to 51°C

Removing/Inserting the Batteries

To insert the batteries, slide the packs into the body of 

the blower. Make sure they latch securely into place.

NOTICE

pack is charged.

•The blower will not work with only one battery pack.

•If one battery pack is completely discharged, the

blower will not function, even if the second battery

Max Air Volume....................................... 17 m³/min

Max Air Speed.......................................... 233 km/h

WARNING

Recharge only with the charger 

specified for the battery. For 

specific charging instructions, read the 

operator’s manual supplied with your charger 

and battery.

WARNING

Always remove the battery 

packs any time the tool is not in 

use. 

The blower requires two charged battery 

packs to operate.

For best results, use with (2) 

MILWAUKEE

®

 

REDLITHIUM

TM

-ION HIGH OUTPUT

TM

 8.0AH or 

higher capacity battery packs.

WARNING

Only use accessories 

specifically recommended for 

this tool. Others may be hazardous.

Tube Assembly

To 

install

, line up the tab on the tube 

with the notch in the housing. Slide the 

tube into the housing until it snaps in 

place. Pull on the tube to ensure it is 

secure. 

To 

remove

 the tube for storage, press 

the tube latch and pull the tube out of 

the housing. Always re-install the tube 

before use.

WARNING

To reduce the risk of injury, do 

not operate blower without tube 

securely in place. Never reach into blower 

through tube hole.

To remove the batteries, push in the release buttons 

and pull the battery pack away from the tool.

FUNCTIONAL DESCRIPTION

1. Flat nozzle
2.
3. Fuel gauge
4. Variable speed lock-on
5. Trigger
6. Handle
7. Air intake vent
8. Tube latch
9. Tube

6

4

7

9

5

8

3

1

2

Tapered nozzle

Summary of Contents for M18 FUEL F2BL

Page 1: ...Cat No BLOWER M18 F2BL M18 FUEL DUAL BATTERY OPERATOR S MANUAL WARNING To reduce the risk of injury user must read and understand operator s manual ...

Page 2: ...at cannot be controlled with the switch is dangerous and must be repaired Do not put hands or objects into openings Do not use with any opening blocked keep free of dust Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations Maintain power tools and accessories ...

Page 3: ...Maintain labels and nameplates These carry important information If unreadable or missing contact a MILWAUKEE service facility for a replacement Regulatory Compliance Mark RCM This product meets applicable regulatory requirements Do not dispose of electric tools together with household waste material Electric tools and electronic equipment that have reached the end of their life must be collected ...

Page 4: ...ely into place NOTICE pack is charged The blower will not work with only one battery pack If one battery pack is completely discharged the blower will not function even if the second battery Max Air Volume 17 m min Max Air Speed 233 km h WARNING Recharge only with the charger specified for the battery For specific charging instructions read the operator s manual supplied with your charger and batt...

Page 5: ...ol battery pack or charger Contact a MILWAUKEE service facility for ALL repairs Keep your tool battery pack and charger in good repair by adopting a regular maintenance program Inspect your tool for issues such as undue noise misalignment or binding of moving parts breakage of parts or any other condition that may affect the tool operation Return the tool battery pack and charger to a MILWAUKEE se...

Page 6: ......

Page 7: ......

Page 8: ...r website Australia Toll Free Telephone Number 1300 645 928 New Zealand Toll Free Telephone Number 0800 645 928 or visit milwaukeetool com au milwaukeetool co nz Please refer to Australian and New Zealand warranty supplied with tool This warranty applies only to product sold by authorised dealers in Australia and New Zealand DESIGNED BY MILWAUKEE ELECTRIC TOOL CORP PROFESSIONALLY MADE IN CHINA PRI...

Reviews: