3
READ AND SAVE
ALL INSTRUCTIONS
FOR FUTURE
REFERENCE.
SYMBOLOGY
Volts
Direct Current
Amps
Read Operator's Manual
SPECIFICATIONS
Charger Cat. No. ......................................M12 TC
Input....................................................5 VDC, 2.1 A
USB Output ........................................9 VDC, 1.6 A
5 VDC, 2.1 A
Operating Temperature
Battery and Charger ..........................4°C to 40°C
(40°F to 104°F)
Battery and Tool ..............................-18°C to 75°C
Power Supply Cat. No. ...................4931 4605 95A
Wall Plug Input Volts ...........................100 - 240 AC
Battery Cat. No........................................... M12B2
Volts .............................................................. 12 DC
Battery Cat. No........................................... M12B3
Volts .............................................................. 12 DC
Battery Cat. No........................................... M12B4
Volts .............................................................. 12 DC
Battery Cat. No........................................... M12B6
Volts .............................................................. 12 DC
FUNCTIONAL
DESCRIPTION
1. USB A port (output)
2. Power cable port (output)
3. Charging indicator LEDs
4. Micro-USB port (input)
5. USB power button
6. Fuel gauge
7. Contacts
8. Release buttons
9. Micro-USB Cable
10. Micro-USB
11. USB A
12. Wall plug prongs
13. Wall plug USB A port (output)
1
2
3
4
5
6
10
7
12
9
11
8
MILWAUKEE
®
LI-ION
BATTERY PACKS
Maintenance and Storage
Do not expose your battery pack or cordless tools
to water or rain, or allow them to get wet. This could
damage the tool and battery pack. Do not use oil or
solvents to clean or lubricate your battery pack. The
plastic casing will become brittle and crack, causing
a risk of injury.
Store battery packs at room temperature away from
moisture. Do not store in damp locations where cor-
rosion of terminals may occur. As with other battery
pack types, permanent capacity loss can result if
the pack is stored for long periods of time at high
temperatures (over 65
o
C).
MILWAUKEE
®
Li-Ion
battery packs maintain their charge during storage
longer than other battery pack types. After about a
year of storage, charge the pack as normal.
Transport
Personal transport of Li-Ion battery packs is allowed
when done in accordance with these warnings and
-
beling, marking, and documentation requirements for
shipping Li-Ion batteries is dependent upon whether
the particular batteries are rated greater than or less
than 100 Wh. Generally, Li-Ion batteries rated 100
Wh or less are “excepted” from certain Class 9 DG
requirements. Always check compliance of Li-Ion
battery consignments against the current regulations
governing the chosen mode of transport. When in
doubt, contact the carrier or other trained Dangerous
Goods professional to confirm acceptability. Li-Ion
(0°F to 167°F)
Regulatory Compliance Mark
(RCM). Product meets applicable
regulatory requirements.
Class III appliance
This charger was only suitable for
indoor use. Never expose the
charger to rain.
13
Output to M12 Battery........................12 VDC, 0.7A
DC Output..........................................12 VDC, 1.5A
ADDITIONAL BATTERY
SAFETY RULES
WARNING
To reduce the risk of fire,
personal injury, and product
damage due to a short circuit, never immerse
your tool, battery pack or charger in fluid or
allow a fluid to flow inside them. Corrosive or
conductive fluids, such as seawater, certain
industrial chemicals, and bleach or bleach
containing products, etc., can cause a short
circuit.
T3.0A
Time-lag fuse 3.0A