background image

5

 

NOTE:

 The cable is not attached to the inner drum. Use 

care to insure that it does not come out of the tool. There 

is a cable end indicator bulb

approximately 

1 m away from the rear end of the cable to indicate a low 

remaining distance.

5. When the clog is reached, pull the front handle into 

the locked position  . Move the tool and cable in a 

back and forth motion until the obstruction is cleared. 

If  the  tool  binds,  release  the  trigger  immediately. 

Repeat until the drain is clear.

To Unbind Drain Snake

1. Set the front handle to the unlocked position 

  

and 

the forward/reverse switch to the reverse position 

.

2. Withdraw the tool a few inches while in reverse to 

free the cable.

3. Stop the tool.

4. After the tool has come to a complete stop, switch 

back to the forward position.

CAUTION

Running  the  tool  in  reverse  for 

 

extended  periods can cause damage 

to the cable and accessories.

Removing Cable From Drain

1. Set the front handle to the unlocked position 

 

and 

the forward/reverse switch to the forward position 

.

2. 

-

3. Release the trigger.

4. Wipe the exposed cable with a rag and feed it back 

into the tool.

5. Repeat steps 2-4 until the cable is free from the drain.

6. Before storing the tool, wash the cable and drum 

(see  "Cleaning  Cables,  Drums  and  Buckets"  in 

Maintenance).

MAINTENANCE

WARNING

To reduce the risk of injury, always 

unplug the charger and remove the 

battery pack from the charger or tool before per

-

forming any maintenance. Never disassemble the 

tool, battery pack or charger. Contact a  

MILWAUKEE

®

 

service facility for ALL repairs.

Maintaining Tool 

Keep your tool, battery pack and charger in good repair 

by adopting a regular maintenance program. Inspect 

your tool for issues such as undue noise, misalignment 

or binding of moving parts, breakage of parts, or any 

other condition that may affect the tool operation. Return 

the tool, battery pack, and charger to a 

MILWAUKEE

®

 

service facility for repair. After six months to one year, 

depending  on use, return the tool, battery pack and 

charger to a 

MILWAUKEE

®

 service facility for inspection.

If the tool does not start or operate at full power with a 

fully charged battery pack, clean the contacts on the bat-

tery pack. If the tool still does not work properly, return 

the tool, charger and battery pack, to a 

MILWAUKEE

®

  

service facility for repairs.

WARNING

To reduce the risk of personal injury 

and  damage,  never  immerse  your 

tool, battery pack or charger in liquid or allow a 

Cleaning

Clean dust and debris from vents. Keep handles clean, 

dry and free of oil or grease. Use only mild soap and a 

damp cloth to clean, since certain cleaning agents and 

solvents  are  harmful  to  plastics  and  other  insulated 

parts.  Some  of  these  include  gasoline,  turpentine, 

lacquer thinner, paint thinner, chlorinated cleaning sol-

vents, ammonia and household detergents containing 

ammonia. Nev

around tools.

Cleaning Cables, Covers, Drums  

and Buckets

Cables, covers, drums and buckets should be thorough-

-

ing effects of sediment and drain cleaning compounds. 

WARNING!

 Wear leather gloves. After washing, dry the 

cable, cover and drum completely. Then, wipe cable with 

an oiled rag before returning it to the drum according to 

the instructions in "Cable Installation".

Repairs

For repairs, return the tool, battery pack and charger to 

the nearest service center.

ACCESSORIES

WARNING

Use only recommended accessories. 

Others may be hazardous.

2. 

NOTE:

 To  avoid  fatigue  or

 

to  free  a  hand  for  easier 

cable  feeding,  the  tool  can be  placed  on  the  flat 

tool base during use.

3. Pull the trigger to begin rotating the cable. 

NOTE:

 The cable can be fed without pulling the trigger, 

but it may feed more easily while rotating.

4. 

Pull at least 450 mm of 

the cable from the tool. 

Insert at least 300 mm of 

cable into the drain, 

placing the drain cleaner 

no more than 150mm 

from the drain opening. 

WARNING!

 Greater 

distance can cause 

twisting, kinking, 

breaking or whipping of 

the cable.

WARNING! 

Wear leather gloves.Grasp the cable 

close to the tool and feed it into the drain about 150 

mm at a time until the obstruction is reached.

Pull the trigger slightly and pull the tool back to 

remove about 300 mm of cable from the drain.

For a complete listing of accessories refer to your 

MILWAUKEE

®

 Tool catalog or go online to 

www.milwaukeetools.com.au / 

www.milwaukeetools.co.nz. To obtain a catalog, 

contact your local distributor or a service centre.

Reviews: