background image

5

180

A

B

5. Move the tool within 1' of wall B. Allow the laser 

to self level. Align the laser cross in the general 

direction of point II on wall B.

A

B

1'

6. Adjust the height of the tool (using the tripod or 

by  adding  shims,  if  required)  to  align  the  laser 

cross directly onto point II on wall B. Allow the 

tool to self-level.

7. Rotate the tool 180° without changing the height, 

allow it to self-level, and mark the center of the 

laser cross on wall A (point III). Point III should 

be aligned as vertically above or below point I on 

wall A as possible.

B

180

A

d

B

8. 

The distance between points I and III on wall A is 

the height deviation (d) of the tool. This distance 

should not exceed 1/8" (max.) at 33' (1/2" at 132'). 

For the Measuring distance of 2 x 66' = 132', the 

maximum allowable deviation (d) is: 132' x ±1/8" 

÷ 33' = ±1/2".

Horizontal Leveling Accuracy 

A free measuring space of approximately 33'x33' on 

a firm surface between two walls or structures A and 

B is required for the check.

It is also suggested to mount the Laser Level to a 

Tripod for easy adjustment. 

Securely mount the tool on one side of the room and 

centered between walls A and B. Direct the laser 

lines toward the other side of the room such that the 

horizontal line appears on both walls A and B. Allow 

the laser to Self-Level.

1. Turn the tool to   ON and to 

 Horizontal 

Level Line mode.

2. At a distance of 16.5' from the laser, mark the 

center of the horizontal line on Wall A (Point I). 

Do the same on Wall B (Point II).

A

B

33'

16.5'

3. Move the Laser 33' toward the opposite wall and 

rotate the laser 180°. Allow the laser to Self-Level.

4. Adjust the height of the tool (using the tripod or 

by adding shims, if required) such that the center 

of the horizontal line is projected exactly against 

the previously marked point II on wall B. Ensure 

the Laser is self-leveled after alignment.

5. Mark the center of horizontal line on wall A (point 

III). Take care that point III is aligned as vertical 

as possible above or below point I.

6. The distance d between marked points I and III on 

wall A indicates the actual deviation (d) of the tool. 

A

B

d

33'

16.5'

7. 

For the Measuring distance of 2 x 33' = 66', the 

maximum allowable deviation (d) is: 66' x ±1/8" ÷ 

33' = ±1/4". Thus, the difference d between points 

I and III should not exceed 1/4" (max.) at 66'.

Summary of Contents for M12 3622-20

Page 1: ...ator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el...

Page 2: ...utside the specified range may damage the battery and increase the risk of fire STORE YOUR BATTERYAND TOOL in a cool dry place Do not store battery where temperatures may exceed 120 F 50 C such as in...

Page 3: ...l ASSEMBLY WARNING Recharge only with the charger specified for the battery For spe cific charging instructions read the operator s manual supplied with your charger and battery Removing Inserting the...

Page 4: ...or 5 8 11 threaded insert to mount on a tripod Once the level is mounted use the micro adjustment knobs to fine tune the laser line OPERATION WARNING To reduce the risk of injury or tem porary effects...

Page 5: ...y adjustment Securely mount the tool on one side of the room and centered between walls A and B Direct the laser lines toward the other side of the room such that the horizontal line appears on both w...

Page 6: ...tool d 9 The maximum vertical deviation d is dmax 2X H door opening x 1 8 33 Example for a door opening height of 7 the maximum permitted deviation d is dmax 2 x 7 x 1 8 33 0 05 Therefore the measurem...

Page 7: ...Electric Lever Hand Chain M12 Heated Gear Reconditioned Product and Test Measurement Products There are separate and distinct warranties available for these products The warranty period for Job Site...

Page 8: ...ntes avec de l eau Si le liquide entre en contact avec les yeux consulter un m decin Le liquide s chappant des batteries peut causer des irritations ou des br lures Ne pas utiliser les blocs piles ni...

Page 9: ...C 4 F to 120 F Plage de travail 38 m 125 Plage d tecteur 50 m 165 Pr cision 3 mm 1 8 10 m 33 Temps d ajustage 3 secondes Montage sur tr pied 1 4 20 5 8 11 Indice de protection IP54 Coefficient de chut...

Page 10: ...regarder directe ment dans le laser lorsqu il est allume ATTENTION L usage de controles de reglages ou de procedures ne figurant pas dans ce manuel peut entrainer l exposition a des rayonnements dange...

Page 11: ...me entre deux murs ou structures A et B est requise Il est aussi conseill de monter le niveau laser sur un tr pied des fins d un ajustage facile 1 Monter fermement l outil une distance approxi mative...

Page 12: ...centre de la ligne horizontale sur le mur A point III Veuillez prendre soin de que le point III s aligne autant vertical que possible sur le point I ou au dessus du ce point 6 La distance d entre les...

Page 13: ...istance entre les points I et III sur le plafond est la d viation d de l outil Cette distance ne devra pas d passer 3 mm 1 8 max 10 m 33 Par rapport la distance de mesure de 2 x 5 m 16 5 10 m 33 a d v...

Page 14: ...D ACHAT DE TOUT PRODUIT MILWAUKEE SI VOUS N ACCEPTEZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE SP CIAL OU IN...

Page 15: ...la posibilidad de que se ocasione interferencia en otros dispositivos ATENCI N El uso de controles o ajustes o el desempe o de los proced imientos que no sean los que se especifican aqu puede provoca...

Page 16: ...m ticamente a modo ahorro si queda menos de 7 de bater a Indicador de carga Para determinar la cantidad de carga que queda en la bater a encienda la herramienta El medidor de combustible se iluminar d...

Page 17: ...os especificados Si se almacenan en calor o fr o excesivo permita que transcurran al menos 2 horas para aclimatarse a temperatura ambiente antes de encender la herramienta Si el problema contin a cont...

Page 18: ...e para un f cil ajuste Monte fijamente la herramienta en un lado de la hab itaci n y centrado entre las paredes A y B Dirija las l neas del l ser hacia el otro lado de la habitaci n de tal forma que l...

Page 19: ...a medida entre los puntos III y IV en la abertura superior de la puerta no debe exceder 1 3 mm 0 05 en una puerta de 2 1 m 7 Precisi n del punto de plomada Se necesita una distancia de medici n libre...

Page 20: ...clavadora de broches 23GA M12 la ribeteadora ciega de 6 4 mm 1 4 M18 FUEL con ONE KEY el raspador de neum ticos de baja velocidad M12 FUEL 58143622d3 00658143622Q0 03 A 02 22 Printed in China MILWAUK...

Reviews: