background image

4

1

2

3

1

3

2

2x AAA

click

ENGLISH

ENGLISH

CHANGE BATTERIES

CORNER PIN

Change batteries 

when battery 

symbol is fl ashing.

BELT CLIP

Summary of Contents for LDM50

Page 1: ...before use Always store the laser distance measurer indoors avoid exposing the tool to shock continuous vibration or extreme temperatures Always keep the tool away from dust liquids and high humidity...

Page 2: ...s Operating Temperature Range 10 C to 50 C Storage Temperature Range 25 C to 70 C Weight without Battery 80 g SPECIFIED CONDITIONS OF USE The laser distance measurer can be used for measuring distance...

Page 3: ...oras 1 push 1x Pythagoras 2 push 2x Pythagoras 3 push 3x MEMORY Timer 3 15 sec push 1x Memory 1 20 push 1x 2 sec Read memory push repeated CHANGE POINT OF MEASURE Front Back Standard automatical Corne...

Page 4: ...4 1 2 3 1 3 2 2x AAA click ENGLISH ENGLISH CHANGE BATTERIES CORNER PIN Change batteries when battery symbol is ashing BELT CLIP...

Page 5: ...5 90 90 90 ENGLISH FUNCTION SWITCH MEASURING REFERENCE PYTHAGORAS Area Starting Point of Measure Pythagoras 1 Front Back Standard automatical Corner Pin Pythagoras 2 Pythagoras 3 Volume Wall Distance...

Page 6: ...6 0 1 2 3 4 5 1 3 5 ENGLISH SINGLE DISTANCE MEASURING...

Page 7: ...7 0 1 2 3 4 2 sec Stop MIN MAX MIN MAX MAX 2 sec 90 2 ENGLISH PERMANENT MINIMUM MAXIMUM MEASURING...

Page 8: ...8 0 1 2 3 1 3 1 000 m 1x 2x ENGLISH ADD SUBTRACT MEASURING...

Page 9: ...9 1 2 1 x 0 1 2 ENGLISH AREA MEASURING...

Page 10: ...10 1 3 2 2 x 0 1 2 3 ENGLISH VOLUME MEASURING...

Page 11: ...11 0 1 2 2 1 90 1 x ENGLISH INDIRECT MEASURING PYTHAGORAS 1...

Page 12: ...12 0 1 2 3 2 x 90 1 3 2 ENGLISH INDIRECT MEASURING PYTHAGORAS 2...

Page 13: ...13 1 2 3 4 1 2 3 90 3 x ENGLISH INDIRECT MEASURING PYTHAGORAS 3...

Page 14: ...14 0 1 2 3 3 x 4 5 1 2 3 4 5 ENGLISH WALL AREA MEASURING SCENARIO 1...

Page 15: ...15 0 1 2 3 4 x 4 5 3 4 5 1 2 ENGLISH WALL AREA MEASURING SCENARIO 2...

Page 16: ...button Push button The seconds are counted down until the measurement starts At 0 the measurement starts The measured values are stored continuously and automatically in memory The stored values can b...

Page 17: ...Level the device and push button Lasericon ashes ashing green illustrated Icon is displayed Icon appears Measured parameter ashes ashing green illustrated Measured value appears brie y in the main li...

Page 18: ...repaeted 7 Exit memory Push button 8 Switch off Push button 2 sec Memory must be exited before Stored values appears in the main line Associated icon appears and measured parameter ashes ashing green...

Reviews: