background image

Adjusting the Side Handle Position

1.  Loosen the side handle clamping collar assembly 

by unscrewing the side handle grip until the side 

handle clamping collar assembly rotates freely. 

2.  

  .

n

o

it

i

s

o

p

 

d

e

ri

s

e

d

 

e

h

o

p

ir

g

 

e

l

d

n

a

h

 

e

d

i

s

 

e

h

e

t

a

t

o

R

3.  Tighten the side handle grip securely.

Installing/Removing the Bit

Slide the bit through the nozzle and then install 

into the tool according to the tool manufacturer's 

instructions. For best results, use a bit 177.8mm (7")

in length or shorter.

Fitting the HAMMERVAC™ to the Tool and Bit

For proper suction and depth

Correct

Incorrect

Incorrect

 

control, position the nozzle as-

the forward face of the nozzle:

1. Press and hold the tool and 

bit depth gauge button. 

2. Push in the nozzle assembly 

front face of the nozzle.

3. Release the tool and bit depth 

gauge button.

NOTE: 

Fully extend the 

HAMMERVAC™ before storing 

to preserve spring life. 

Setting the Drilling Depth

1. Fit the HAMMERVAC™ to the Tool and Bit.

2. Press and hold the depth gauge button and slide 

the depth gauge to the desired depth. The drill-

ing depth is the last visible measurement shown 

when viewed from the depth gauge on the top of 

the tool. To ensure the HAMMERVAC™ is prop-

erly set to the tool, bit, and desired depth, always 

drill a test hole.

OPERATION

WARNING

-

-

mable or combustible materials. Empty dust box 

completely before use.
To reduce the risk of injury, always wear proper 

eye protection marked to comply with AS/NZS 
1337.1. When working in dusty situations, wear 

appropriate respiratory protection or use a suit-

able dust extraction solution.

Using the Power Switch

AUTO

  To set the HAMMERVAC™ to start auto-

matically as a hole is being drilled, move 

  .

n

o

it

i

s

o

p

 

O

T

U

A

 

e

h

t

 

o

t

 

h

c

ti

w

s

 

r

e

w

o

p

 

e

h

t

When the nozzle assembly is pushed in, 

the HAMMERVAC™ will run. 

NOTE:

 The 

HAMMERVAC™ will continue to run 3-5 

seconds after the tool has fully extended to 

ensure all dust is captured in dust box.

ON 

  To turn the tool 

ON

, move the power switch 

to the ON position. The HAMMERVAC™ will 

run continuously.

OFF

 

To turn the tool 

OFF

, move the power switch 

to the 

OFF

 position. 

NOTE:

 When the HAMMERVAC™ has come to a 

of debris that could become lodged.

Proper Operation

1. Empty the dust box.

NOTE: 

For optimal use to remove debris in the 

dust box, connect a hose to a vaccum and re-

move debris. 

2. Install and position the nozzle assembly to the 

desired side.

3. Attach side handle clamping collar assembly and 

grip to tool.

4. Fit the HAMMERVAC™ to the Tool and Bit.

5. Set the drill depth.

6. Install the battery pack.

7. Turn HAMMERVAC™ to 

ON

 or AUTO.

8. Begin use according to tool manufacturer instruc-

tions.

9. Always hold the tool securely using both handles 

to maintain control. 

Attaching the HAMMERVAC™ to a Rotary 

Hammer/Hammer Drill

The HAMMERVAC™ is provided with a clamping 

collar assembly and one side handle grip.

1. Turn 

OFF

, remove the battery pack from the 

HAMMERVAC™, and disconnect power from 

the tool.

2. Remove the tool side

handle by flipping 

clamp lever upwards. 

3.  S l i d e  

t h e 

HAMMERVAC™ side 

handle clamping col-

lar assembly over the 

chuck and onto the 

neck of the tool.

4. Attach the side handle 

clamping collar assem-

then lower jaw.

5. Press down the clamp lever to secure the clamping 

collar assembly to the HAMMERVAC™. 

6. Rotate the HAMMERVAC™ and side handle grip 

to the desired position and tighten securely. 

5

NOTE: 

When using the optional Crevice Tool (Cat. 

No. 49-90-2325),  set the drill depth to 0.

Drill Depth

Clamp

lever

Upper

Jaw

Lower

Jaw

Summary of Contents for HAMMERVAC M12 UDEL

Page 1: ...OPERATOR S MANUAL WARNING To reduce the risk of injury user must read and understand operator s manual Cat No L M12 HAMMERVAC UNIVERSAL DUST EXTRACTOR...

Page 2: ...ly manufacturer s recommended attachments USE AND CARE liquids such as gasoline or use in areas where they may be present Do not pick up anything that is burning or smok ing such as cigarettes matches...

Page 3: ...DESCRIPTION Side handle clamp attachment point 1 Dust box latch 2 Depth gauge button 3 Nozzle release lever 4 Nozzle 5 Nozzle assembly 6 Dust box with filter 7 8 Side handle clamping collar assembly...

Page 4: ...pull the the dust box and tap HEPA filter away from clean Do not clean with water or compressed air After about 1500 HEPA filter Cat No 49 90 2306 To install the dust box 1 Slide the dust box into the...

Page 5: ...auto matically as a hole is being drilled move n o i t i s o p O T U A e h t o t h c t i w s r e w o p e h t When the nozzle assembly is pushed in the HAMMERVAC will run NOTE The HAMMERVAC will contin...

Page 6: ...ular maintenance program Inspect your tool for issues such as undue noise misalignment or binding of moving parts breakage of parts or any other condition that may affect the tool operation Return the...

Page 7: ......

Page 8: ...our website Australia Toll Free Telephone Number 1300 645 928 New Zealand Toll Free Telephone Number 0800 645 928 or visit milwaukeetool com au milwaukeetool co nz Please refer to Australian and New...

Reviews: