background image

CAUTION

HAMMERVAC™ is largely depen-

clean with water or compressed air. Remove from 

dust box and tap clean.

Installing/Removing Nozzle Assembly

To install the nozzle assembly

supplied with the tool, or acces-

sory nozzles:                

1.  With the nozzle assembly 

pointing straight up, line up the 

lugs of the nozzle assembly 

with the lugs on the front of the 

HAMMERVAC™. The unlock 

symbol 

on the nozzle as-

sembly will line up with the 

depth gauge on the top of the 

HAMMERVAC™.

2.  Turn the nozzle assembly left

or right to lock into place. The 

lock symbol  on the nozzle 

assembly will line up with the 

depth gauge on the top of the 

HAMMERVAC™.

3. To remove, reverse the proce-

dure.

Installing/Removing Nozzle

Replace the nozzle:                        

 After drilling about 1500 holes,

 When the bit brush shows signs 

of wear,

 When suction is reduced, 

 When dust escapes through the 

bit brush during use 

To replace the Standard (Cat. 

N o .   1 4 - 5 2 - 0 1 0 5   a n d   L a r g e 

Cat. No. 14-52-0110) nozzles, ro-

tate the nozzle release lever up to 

the open position and pull out nozzle from the lower 

nozzle assembly(Cat. No. 42-20-0615). Slide the new 

nozzle into the lower nozzle assembly and rotate the 

nozzle release lever down to the closed position. 

SPECIFICATIONS

Cat. No. .................................................M12 UDEL

Dust Box Cat. No .................................. 42-16-0580

Crevis Tool Cat. No ............................... 49-90-2325

Volts............................................................12V DC

Battery Type .................................................M12™

Charger Type................................................M12™

Max depth........................................... 203 mm (8”)

 

Min Bit Diameter ................................ 4 mm (5/32") 

Max Bit Diameter............................. 32mm (1-1/4") 

Hammer Collar Sizes 

  Diameter  

Circumference

  Ø 41-61 mm (1.6"-2.4")   

129-192  mm  (5.1"-7.5")

Recommended Ambient Operating Temperature 

 

...................................-17°C to 51°C (0°F to 125°F)

Dust box 

port

HEPA 

 

6. If  necessary,  pull the 

the dust box and tap 

HEPA filter away from

clean. Do not clean 

with water or compressed air. After about 1500 

HEPA filter (Cat. No. 49-90-2306).

To 

install 

the dust box:

1. Slide the dust box into the body of the 

HAMMERVAC™. 

2. The dust box latches should snap into place.

NOTE: 

 Do not operate the HAMMERVAC™ without 

ADDITIONAL BATTERY SAFETY RULES

WARNING

To reduce the risk of fire, 

personal injury, and product

damage due to a short circuit, never immerse your 

tool, battery pack or charger in fluid or allow a fluid 

to flow inside them. Corrosive or conductive fluids, 

such as seawater, certain industrial chemicals, and 

bleach or bleach-containing products, etc., can 

cause a short circuit. 

 

WARNING

Do not charge 

non-rechargeable batteries.

4

ASSEMBLY

WARNING

Recharge only with the charger 

-

manual supplied with your charger and battery.

Removing/Inserting the Battery

To 

remove

 the battery, push in the release buttons 

and pull the battery pack away from the tool.

WARNING

Always remove battery pack before 

changing or removing accessories. 

To 

insert

 the battery, slide the pack into the body 

of the tool. Make sure it latches securely into place.

WARNING

recommended for this tool. Others 

may be hazardous.
To reduce the risk of injury, always remove the 

battery pack before removing the dust box. Do 

in place. 

Installing/Removing the Dust Box

and HEPA Filter

To

 remove

 the dust box:

1.  Turn 

OFF

 the tool.                   

2. Remove the battery pack.  

3. Press the dust box latches. (1)

4. Pull the dust box away from the

1

2

 

HAMMERVAC™. (2)

5. Empty debris by holding away 

from the user’s face and tap-

ping dust box into a trash can, 

pail, or other reasonable con-

tainer. For best cleaning

results, connect a 

vacuum hose with dust 

extraction adaptor (Cat 

No. 49-90-1959) to the 

dust box port and suc-

tion out debris.

Summary of Contents for HAMMERVAC M12 UDEL

Page 1: ...OPERATOR S MANUAL WARNING To reduce the risk of injury user must read and understand operator s manual Cat No L M12 HAMMERVAC UNIVERSAL DUST EXTRACTOR...

Page 2: ...ly manufacturer s recommended attachments USE AND CARE liquids such as gasoline or use in areas where they may be present Do not pick up anything that is burning or smok ing such as cigarettes matches...

Page 3: ...DESCRIPTION Side handle clamp attachment point 1 Dust box latch 2 Depth gauge button 3 Nozzle release lever 4 Nozzle 5 Nozzle assembly 6 Dust box with filter 7 8 Side handle clamping collar assembly...

Page 4: ...pull the the dust box and tap HEPA filter away from clean Do not clean with water or compressed air After about 1500 HEPA filter Cat No 49 90 2306 To install the dust box 1 Slide the dust box into the...

Page 5: ...auto matically as a hole is being drilled move n o i t i s o p O T U A e h t o t h c t i w s r e w o p e h t When the nozzle assembly is pushed in the HAMMERVAC will run NOTE The HAMMERVAC will contin...

Page 6: ...ular maintenance program Inspect your tool for issues such as undue noise misalignment or binding of moving parts breakage of parts or any other condition that may affect the tool operation Return the...

Page 7: ......

Page 8: ...our website Australia Toll Free Telephone Number 1300 645 928 New Zealand Toll Free Telephone Number 0800 645 928 or visit milwaukeetool com au milwaukeetool co nz Please refer to Australian and New...

Reviews: