background image

22

22

XII

English

For battery pack storage longer than 30 days: Store the battery 

pack where the temperature is below 27°C and away from moisture 

Store the battery packs in a 30% - 50% charged condition Every six 

months of storage, charge the pack as normal.
Do not dispose of used battery packs in the household refuse or 

by burning them. Milwaukee Distributors offer to retrieve old 

batteries to protect our environment.
Do not store the battery pack together with metal objects (short 

circuit risk).
No metal parts must be allowed to enter the battery section of the 

charger (short circuit risk).
Battery acid may leak from damaged batteries under extreme load 

or extreme temperatures. In case of contact with battery acid wash 

it off immediately with soap and water. In case of eye contact rinse 

thoroughly for at least 10 minutes and immediately seek medical 

attention.

BATTERY PACK PROTECTION

In extremely high torque, binding, stalling and short circuit situa-

tions that cause high current draw, the tool will vibrate for about 5 

seconds, the fuel gauge will flash,and then the tool will turn OFF.  

To reset, release the trigger. Under extreme circumstances, the 

internal temperature of the battery pack could raise too much. If 

this happens, the fuel gauge will flash until the battery pack cooled 

down. After the lights go off, the work may continue.
Place the battery on the charger to charge and reset it.

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods Legisla-

tion requirements.
Transportation of those batteries has to be done in accordance with 

local, national and international provisions and regulations.
The user can transport the batteries by road without further 

requirements.
Commercial transport of Lithium-Ion batteries by third parties is 

subject to Dangerous Goods regulations. Transport preparation and 

transport are exclusively to be carried out by appropriately trained 

persons and the process has to be accompanied by corresponding 

experts.
When transporting batteries:
Ensure that battery contact terminals are protected and insulated 

to prevent short circuit.
Ensure that battery pack is secured against movement within 

packaging.
Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice

MAINTENANCE

Before use check machine, cable, safety harness and plug for any 

damages or material fatigue. Repairs should only be carried out by 

authorised Service Agents.
The ventilation slots of the machine must be kept clear at all times.
From time to time, apply a few drops of oil to the rack toothing. The 

bearings of the feed shaft are self-cutting and must not be greased. 

Grease the sliding surface of the carriage with Molykote grease.
Clean dust and debris from tool. Keep tool handles clean, dry and 

free of oil or grease. Use only mild soap and a damp cloth to clean 

the tool since certain cleaning agents and solvents are harmful 

to plastics and other insulated parts. Never use flammable or 

combustible solvents around tools.
Use only Milwaukee accessories and Milwaukee spare parts. Should 

components need to be replaced which have not been described, 

please contact one of our Milwaukee service agents (see our list of 

guarantee/service addresses). 
If needed, an exploded view of the tool can be ordered. Please 

state the Article No. as well as the machine type printed on the 

label and order the drawing at your local service agents or directly 

at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Win-

nenden, Germany.

SYMBOLS

CAUTION! WARNING! DANGER!

Remove the battery pack before starting any work on the 

appliance.
Always work in pairs when using the drill stand above 

head height. Carry the electric tool between the two of 

you to avoid suffering back injuries.
Please read the instructions carefully before starting the 

machine.

Always wear goggles when using the machine.

Wear ear protectors!

Wear gloves!

DANGER! To reduce the risk of injury, always keep hands, 

rags, clothing, etc. away from moving parts and chips. Do 

not try to remove chips while the cutter is rotating. Chips 

are sharp and can pull objects into moving parts.

Carrying along metal parts and watches is prohibited.

Persons with cardiac pacemakers or other medicinal 

implants may not use this drill stand.

Carrying of magnetic or electronic media prohibited.

Never expose tool to rain.

Summary of Contents for 4933451012

Page 1: ...Original instructions M18 FMDP...

Page 2: ...4 4 5 5 16 16 8 8...

Page 3: ...VIII X II VII VI IX I III V XI IV Technical Data Safety Instructions Specified Conditions of Use Declaration of Conformity Batteries Maintenance Symbols Please read and save these instructions XII...

Page 4: ...2 2 I 1 2 M18B9 9 0 Ah M18HB 12 0 Ah...

Page 5: ...3 3 I 1 1 2 2...

Page 6: ...4 4 I 78 100 33 54 55 77 10 32 10...

Page 7: ...5 5 II 1 1 2 2...

Page 8: ...6 6 III A B...

Page 9: ...7 7 III 1 4 3 2 2 1...

Page 10: ...8 8 IV 1 2 3...

Page 11: ...9 9 V Cutting fluid 1 3 ON OFF 2...

Page 12: ...10 10 V...

Page 13: ...11 11 VI 1 4 6 35 mm 1 4 6 35 mm...

Page 14: ...12 12 VI OFF ON...

Page 15: ...13 13 VII START STOP...

Page 16: ...14 14 VIII 1 2 3 TEST 4...

Page 17: ...15 15 VIII 7 8 9 10 5 6 START STOP...

Page 18: ...16 16 VIII 11 12 A B...

Page 19: ...17 17 IX 2 3 5 6 4 1...

Page 20: ...18 18 X Setting the free motion of the slide 1 2 3...

Page 21: ...19 19 XI...

Page 22: ...ctuallydoingthejob Thismaysignificantlyreducetheexposureleveloverthetotalworkingperiod Identify additional safety measures to protect the operator from the effects of vibration such as maintain the to...

Page 23: ...tool as a result of too high a feed rate unclean magnetic surface Switch the machine off and then switch it back on again RESTART CUTOUT If the machine is still switched on it will not restart after...

Page 24: ...ed and insulated to prevent short circuit Ensure that battery pack is secured against movement within packaging Do not transport batteries that are cracked or leak Check with forwarding company for fu...

Page 25: ...and batteries that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Check with your local authority or retailer for recy...

Page 26: ...right Techtronic Industries GmbH Max Eyth Stra e 10 71364 Winnenden Germany 49 0 7195 12 0 www milwaukeetool eu Techtronic Industries UK Ltd Fieldhouse Lane Marlow Bucks SL7 1HZ UK 11 20 4100 4250 95...

Reviews: