Maintenance

Due to fan’s natural movement, connections may get loose after a period of usage. 

To ensure a proper and safety usage,We highly recommend to inspect and tighten all connections 

every 6 months.

CLEANING

Clean your fan periodically to prolong its new appearance. Basic cleaning procedures are as follows:

1.Use only lukewarm water. Do not use detergent, corrosive or acidic solution.

2.Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will 

   scratch the surface.

3.Apply a thin coat of furniture polish to the wooden blades to protect and enhance the appearance.

4.To cover small scratches, apply a light coat of shoe polish over it.

5.There is no need to lubricate the fan.

Troubleshooting

Check on the following before lodging a service report

SYMPTOM                        PROBLEM                                           SOLUTION

Fan not moving       1.Main cables not connected        1.Check main and branch circuit 

                                                                                         Breakers or fuse

                                 2.Wire connection loose              2.Check the line wires connections 

                                                                                         to the fan and switch housing  

Fan noisy                 1.Housing screws are loose         1.Tighten all screws

                     

                                 2.Wire and nut connections         2.Neatly separate and store the wire

                                     rattles against each other            connections from the nut

                                 3.Canopy touches the ceiling       3.Check to ensure the canopy is not 

                                                                                         touching or too close to the 

                                                                                         Ceiling

Remote control         1.Remote and receiver code       1.Check that the codes are exactly 

Not working                 different                                        the same

                                 2.Battery not installed                   2.Install the remote control battery

                                 3.Weak battery                             3.Change a new battery

 

 

 

Summary of Contents for MCF- E120

Page 1: ...or installing reference only Model MILUX SALES SERVICE SDN BHD Head Office No 31 Lorong Jala 14 KS10 Off Jalan Telok Gong 42000 Port Klang Selangor Malaysia Tel 603 31341254 Fax 603 31341193 Toll Free...

Page 2: ...connection are tightly screwed and secured 10 An all pole disconnection must be incorporated in the fixed wiring in accordance with the wiring rules a all pole disconnection incorporated in the fixed...

Page 3: ...er pin Fig 3 2 Downrod Installation a b c d e 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Qty Parts 1 1 Downrod 2 1 Ceiling canopy 3 1 Yoke cover 4 1 Fan motor assembly 5 3 Fan blade 6 1 Bottom cover 7 1 set Balance...

Page 4: ...4 Place the pulley onto the Hook Fig a 5 Lift the motor until the bracket hole of the downrod aligning the pulley hole Tighten the downrod to the pulley with the previous bolt washer nut and contter p...

Page 5: ...d Safety Cable must be fixed correctly May cause injury if ceiling fan drops Screw Screw Safety Cable 1 2 3 Install Safety Cable Blades Installation Blade Blade screws Flat washer 1 Insert the blade s...

Page 6: ...ckwise Fig 9 1 Remove the 4 light kit screws from switch housing 2 Connect the quick connector and then put them into the switch housing 3 Attached the light kit to switch housing and align the screw...

Page 7: ...ieces of lead wires from the screws bag and connect the wire to the fan Fig 11 4 Connect the fan wire to the house s supply wire Diagram shows a complete assembly of the ceiling fan Fig 12 Fig 13 5 Fi...

Page 8: ...light coat of shoe polish over it 5 There is no need to lubricate the fan Troubleshooting Check on the following before lodging a service report SYMPTOM PROBLEM SOLUTION Fan not moving 1 Main cables...

Page 9: ...rt a fault please contact our customer service center at MILUX SALES SERVICE SDN BHD 302263 X No 31 Lorong Jala 14 KS10 Off Jalan Telok Gong 42000 Port Klang Selangor Malaysia Tel 603 31341254 Toll Fr...

Reviews: