Sterylis BASIC MANUAL
| 13
6.3 Starting the device and selecting the operating mode
The device can operate in several operating modes, the activation of which is forced by means of appropriate buttons on
the user panel. The following modes are available: Filtration, UV-C air disinfection - standard mode, UV-C air disinfection -
silent mode and UV-C air disinfection - automatic.
To start the device, insert the power cord plug into an electrical outlet. The voltage required for proper operation is 230 V,
50 Hz. Then move the user panel switch to the “I” position.
When the device is started, it will be in standby mode, which means that it is ready for operation and waiting for a
command from the user. The display in the AUTOMATIC MODE section shows "Aut.x".
6.3.1 “Filtration” mode
To start the "Filtration" mode of operation, press and hold the START button located at the green filtering mode indicator.
The filter mode light will start blinking (the device will check the proper functioning of the relevant actuators - PRE-TEST
function) and then it will start to light steadily and the device will start working in the selected mode.
If any errors are detected during the PRE-TEST function, the device will display a tESt message, enter the standby mode
and then display the corresponding error codes on the display in the AUTOMATIC MODE section.
The filtration mode can also be directly selected if the device operates in any of the disinfection modes. To switch from
disinfection mode to filtration mode, press and hold the START button located at the green filtration mode light.
To interrupt the filtration process, press and hold the START button located at the green filtration mode light again.
6.3.2 “UV-C air disinfection - standard mode” operating mode
To start the "UV-C air disinfection - standard mode" operating mode, press and hold the START button located at the
green standard mode light. The standard mode light will start blinking (the device will check the proper functioning of the
relevant actuators - PRE-TEST function) and then it will start to light steadily and the device will start working in the
selected operation mode.
If any errors are detected during the PRE-TEST function, the device will display a tESt message, enter the standby mode
and then display the corresponding error codes on the display in the AUTOMATIC MODE section.
During operation of the device in disinfection mode, the display in the UV-C section is activated as standard.
The standard mode can also be directly selected if the device operates in any of the disinfection or filtration modes. To
switch from disinfection or filtration mode to standard disinfection mode, press and hold the START button located at the
green standard mode light.
To interrupt the standard disinfection process, press and hold the START button next to the green standard mode light
again.
6.3.3 “UV-C air disinfection – silent mode” operating mode
To start the "UV-C air disinfection - silent mode" operating mode, press and hold the START button located at the green
silent mode light. The silent mode light will start blinking (the device will check the proper functioning of the relevant
actuators - PRE-TEST function) and then it will start to light steadily and the device will start working in the selected
operation mode.
If any errors are detected during the PRE-TEST function, the device will display a tESt message, enter the standby mode