3.4.
Dribbling: Locate the entire chemical line below the machine inlet.
—
Assuming the chemical system does not retain any line pressure and that the pump provides
positive closure when the system is off, locate the entire chemical delivery line below the level of
the chemical inlet. An example of this is shown in Figure 4.
Figure 4:
Locating a Pumped Chemical System With Positive
Closure To Protect Against Machine Damage
Example of Correct Placement
Legend
I.
Chemical inlet on
machine
L.
Chemical delivery line
P.
Pump with positive
closure when system is
off
T.
Chemical tank
4.
Guarding Against Leaks
All personnel who may work with the chemical system (e.g., chemical system manufacturer,
chemical system supplier, chemical supplier, operator, maintenance personnel) should be vigilant
in observing for leaks in the system. When connecting, or reconnecting chemical lines, whether at
installation, after taking samples, or when replacing components, at a minimum ensure that:
1. the proper components are used,
2. all connections are the proper fit, and
3. all components are securely connected.
CAUTION 2 : Injury and Damage Hazards
—Chemicals leaking from a chemical system
may be corrosive or toxic. Such chemicals can injure personnel and damage equipment.
• Use care when connecting chemical lines.
• Inspect regularly for leaks.
— End of BIWUUI03 —
19
Summary of Contents for 30015C4E
Page 6: ...2 ...
Page 8: ...4 ...
Page 24: ...20 ...
Page 25: ...Section 1 Service and Maintenance 21 ...
Page 49: ...Section 2 Drive Assemblies 45 ...
Page 54: ...50 ...
Page 55: ...Section 3 Bearing Assemblies 51 ...
Page 69: ...Section 4 Shell and Door Assemblies 65 ...
Page 78: ...74 ...
Page 79: ...Section 5 Control and Sensing 75 ...
Page 87: ...Section 6 Chemical Supply 83 ...
Page 89: ...Section 7 Water and Drain 85 ...