MANUAL DE UTILIZAÇÃO |
BALANÇO HIDRÁULICO
40
www.mills.com.br
2.1.7.1. RULE FOR USING DOUBLE BASE
Minimum opening for support in the
double base use: 10 cm.
ADJUSTMEHTS FOR DOUBLE BASE
B
MAIN AND
SECONDARY
BEAMWORK
MINIMUM BEAM HEIGHT
MAXIMUM BEAM HEIGHT
A
SLAB THICKNESS (cm)
SLAB THICKNESS (cm)
10
15
20
25
10
15
20
25
B
VA165 and VA140
52,5
57,5
62,5
67,5
72,5
77,5
82,5
87,5
VA140 and VA140
50,5
55,5
60,5
65,5
70,5
75,5
80,5
85,5
VA140 and VJ3”
43,5
48,5
53,5
58,5
63,5
68,5
73,5
78,5
VJ5” and VJ3”
42,0
47,0
52,0
57,0
62,0
67,0
72,0
77,0
DETAIL
≥10cm
A
B
In order to perform the stripping
of the slab it is necessary to
leave at least 10 cm of thread in
the supports
(A)
positioned on
the double base
(B)
.
A
B
◄
Schematic detail for designs
using double base.