OM-227398 Page 6
SECTION 4 − SPECIFICATIONS
4-1.
Specifications
Model
Welding Output Range
Electrode
Wire Diameter
Capacity
Wire Feed
Speed Range
Net Weight
(Torch Only)
XR-A AlumaPro 15 ft (4.7 m)
XR-A AlumaPro 25 ft (7.6 m)
XR-A AlumaPro 35 ft (10.7 m)
300 A at 100% Duty Cycle
.030 To 1/16 in.
(0.8 To 1.6 mm)
aluminum wire
70 To 900 ipm
(1.8 To 23 mpm)
2.5 lb (1.1 kg)
(less cables)
(CE And Non CE Models)
XR-W AlumaPro 15 ft (4.7 m)
XR-W AlumaPro 25 ft (7.6 m)
XR-W AlumaPro 35 ft (10.7 m)
400 A at 100% Duty Cycle
.030 To 1/16 in.
(0.8 To 1.6 mm)
aluminum wire
70 To 900 ipm
(1.8 To 23 mpm)
2.9 lb (1.3 kg)
(less cables)
.
When using 1/16 in (1.6 mm) wire, kit 230708 must be installed.
4-2.
Environmental Specifications
A. IP Rating
IP Rating
IP3X
This equipment is designed for indoor use and is not intended to be used or stored outside.
IP3X 2014−06
B. Temperature Specifications
Operating Temperature Range
Storage Temperature Range
14 to 104
°
F (−10 to 40
°
C)
−4 to 131
°
F (−20 to 55
°
C)
Temp_2016- 07
C. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
Notes
Summary of Contents for XR-AlumaPro Series
Page 38: ...Notes...