![Miller XMT350 CC/CV Auto-Line CE Owner'S Manual Download Page 36](http://html1.mh-extra.com/html/miller/xmt350-cc-cv-auto-line-ce/xmt350-cc-cv-auto-line-ce_owners-manual_1796314036.webp)
A complete Parts List is available at www.MillerWelds.com
OM-2254 Page 30
SECTION 8 − GMAW/FCAW OPERATION
8-1.
Typical Connection For Remote Control Feeder GMAW/FCAW Process
264 343-A
!
Turn off power before making
connections.
1
Remote 14-Receptacle
2
Positive (+) Weld Output Terminal
3
Negative (−) Weld Output Terminal
4
Ground Cable to Workpiece
5
Workpiece
6
Gun
7
Wire Feeder
8
Gas Hose
9
Gas Cylinder
Use of shielding gas is dependant on Wire
Type.
The connection diagram illustrates
DCEP (reverse polarity) suitable for all
wires except self-shielded FCAW. The
majority of self-shielded FCAW wires
require DCEN (straight polarity).
3
4
5
6
7
8
9
1
2
Summary of Contents for XMT350 CC/CV Auto-Line CE