TM-257 220 Page 12
XMT 450 CC/CV
4-3.
Connecting Weld Output Cables
803 778-B
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.
1
Weld Output Terminal
2
Supplied Weld Output Terminal Nut
3
Weld Cable Terminal
4
Copper Bar
Remove supplied nut from weld output ter-
minal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
Tools Needed:
3/4 in. (19 mm)
4
2
3
Do not place
anything between
Incorrect Installation
1
weld cable terminal
and copper bar.
4-4.
Remote 14 Receptacle Information
A
J
B
K
I
C
L
N
H
D
M
G
E
F
Ref. 252 018-A
Socket*
Socket Information
24 VOLTS AC
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC con-
tactor control circuit.
REMOTE
CONTROL
C
Output to remote control; +10 volts DC in MIG
mode. 0 to +10 volts DC in other modes.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control.
M
CC/CV select 0 to +10 volts DC.
A/V
AMPERAGE
VOLTAGE
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 arc volts.
GND
G
Circuit common for 24 volt AC circuit.
K
Chassis common.
*The remaining sockets are not used.
Summary of Contents for XMT 450 CC
Page 4: ......
Page 68: ...TM 257 220 Page 64 XMT 450 CC CV Notes...
Page 71: ...TM 257 220 Page 67 XMT 450 CC CV 256 909 A...
Page 73: ...TM 257 220 Page 69 XMT 450 CC CV 256 916 C...
Page 75: ...TM 257 220 Page 71 XMT 450 CC CV 256 916 C...
Page 76: ...TM 257 220 Page 72 XMT 450 CC CV Notes...
Page 83: ...Notes...