8-6. Troubleshooting
Trouble
Remedy
No weld output; unit completely
inoperative.
Place line disconnect switch in On position.
Check and replace line fuse(s), if necessary, or reset supplementary protector.
Be sure power cord is plugged in and that receptacle is receiving input power.
No weld output; unit is on.
Check and secure loose weld cable(s) into receptacle(s).
Check and correct poor connection of work clamp to workpiece.
Erratic or improper welding arc or
output.
Use proper size and type of weld cable (see your Distributor).
Clean and tighten weld connections.
Verify electrode polarity; check and correct poor connections to workpiece.
Fan not operating.
Unit not warmed up enough to require fan cooling.
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor and control circuitry.