![Miller MigMatic 220 Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/miller/migmatic-220/migmatic-220_owners-manual_1796189012.webp)
OM-246 691 Page 8
SECTION 3 − SPECIFICATIONS
3-1.
Serial Number And Rating Label Location
The serial number and rating information for this product is located on back panel
. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
3-2.
Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-5 and 4-6 for information on con-
necting input power.
Model
Rated Output
Max. Open
Circuit
Voltage
Amperage
Range
DC
Dimension (mm)
Weight
(kg)
100%
60%
20%
220
230 VAC 50/60
Hz
90 A
18.5 V
116 A
19.8 V
200 A
24.0 V
40.2
30-200 A
480 x 712 x 920
66 Net
Wire feed speed range 1.3 mpm to 20 mpm.
Model
Rated Output
Max. Open
Circuit
Voltage
Amperage
Range
DC
Dimension (mm)
Weight
(kg)
100%
60%
35%
250
230/400 VAC
50/60 Hz
145 A
21.0 V
190 A
23.0 V
250 A
26.5 V
43.0 V
30-250 A
480 x 712 x 920
73 Net
Wire feed speed range 1.3 mpm to 20 mpm.
3-3.
Environmental Specifications
A. IP Rating
IP Rating
Operating Temperature Range
IP23S
This equipment is designed for outdoor use. It
may be stored, but is not intended to be used
for welding outside during precipitation unless
sheltered.
-10 to 40
°
C (14 to 104
°
F)
IP23S 2014−06
B. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
ce-emc 4 2014-07
Summary of Contents for MigMatic 220
Page 19: ...OM 246 691 Page 15 Notes...
Page 37: ...OM 246 691 Page 33 956142710 B Figure 7 2 Circuit Diagram for Migmatic 250 230 400 VAC...
Page 38: ...OM 246 691 Page 34 956142711 F Figure 7 3 Circuit Diagram for Migmatic 220 DX 230 VAC...
Page 39: ...OM 246 691 Page 35 956142712 E Figure 7 4 Circuit Diagram for Migmatic 250 DX 230 400 VAC...