OM-1330 Page 9
SECTION 3
−
DEFINITIONS
3-1. Symbols And Definitions
Wire Feed
Output
X
Duty Cycle
Do Not Switch
While Welding
V
Volts
Increase
On
Off
Gas Metal Arc
Welding (GMAW)
Gun
Wire Feed Spool
Gun
Gas Input
Gas Output
Voltage Input
Press To Reset
U
0
Rated No-Load
Voltage (Average)
SECTION 4
−
INSTALLATION
4-1. Specifications
A. 115 VAC
Rated Welding
Output
Amperage Range
Maximum Open-Cir-
cuit Voltage DC
Amperes Input at Rated
Load Output 115 V, 60 Hz,
Single-Phase
KVA
KW
68 A @ 19.5 Volts DC*,
20% Duty Cycle
30
−
135
32
15
2.27
1.85
90 A @ 18.0 Volts DC, 20%
Duty Cycle
30
−
135
32
20
2.78
2.23
* CSA Rating
B. 230 VAC
Rated Welding
Output
Amperage Range
Maximum Open-Cir-
cuit Voltage DC
Amperes Input at Rated
Load Output 230 V, 50/60
Hz, Single-Phase
KVA
KW
150 A @ 23 Volts DC, 40%
Duty Cycle
30
−
175
32
25.0
5.74
4.93
C. General Specifications
Wire Type and Diameter
Wire Feed
Speed
Maximum
Spool Size
Dimensions
Net Weight w/
Gun
Solid/Stainless
Flux Cored
Aluminum
50
−
600 IPM
(1 3 15 2
12 in (305 mm)
Diameter
H: 32 in (813 mm)
W: 19 in (483 mm)
168 lb
(76 kg)
.023
−
.035 in
(0.6
−
0.9 mm)
.030
−
.035 in
(0.8
−
0.9 mm)
.030
−
.035 in
(0.8
−
0.9 mm)
(1.3
−
15.2
m/min)
Diameter
33 lb (15 kg)
W: 19 in (483 mm)
D: 39 in (991 mm)
(76 kg)