OM-4430 Page 36
D. Engine
Trouble
Remedy
Engine will not crank.
Check fuse F6, and replace if open (see Section 8-6).
Check battery voltage.
Check battery connections and tighten if necessary.
Check plug PLG5 and plug PLG8 connections.
Have Factory Authorized Service Agent check Engine Control switch S2.
Engine does not start.
Check fuel level (see Section 5-2).
Check battery and replace if necessary.
Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 according to engine manual.
Check engine charging system according to engine manual.
See engine manual.
Engine starts but stops when Engine
Control switch returns to either Run/
Idle position.
Check oil level (see Section 5-2). Low oil pressure shutdown stops engine if oil pressure is too low.
Engine also stops if oil level is too high.
Use correct grade oil for operating temperature. (see Section 8-2).
Have Factory Authorized Service Agent check low oil pressure shutdown switch S5.
Battery discharges between uses.
Place Engine Control switch in Off position when unit is not running.
Clean top of battery with baking soda and water solution; rinse with clear water.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check voltage regulator according to engine manual.
Engine stopped during normal
operation.
Check fuel level (see Section 5-2).
Check oil level (see Section 5-2). Low oil pressure shutdown stops engine if oil pressure is too low.
Engine also stops if oil level is too high.
Have Factory Authorized Service Agent check low oil pressure shutdown switch S5.
Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 according to engine manual.
Engine does not return to idle speed.
Place Engine Control switch S2 in either Run/Idle position.
Remove all weld and generator power loads.
Turn off remote contactor. The unit will not return to idle speed when the remote contactor is on.
Turn off remote device connected to Remote receptacle RC4 (see Section 5-7).
Check for obstructed movement of solenoid linkage.
Have Factory Authorized Service Agent check circuit board PC2.
Engine does not go to weld speed.
Place Speed Control switch in Weld position.
Check for obstructed movement of solenoid linkage.
Summary of Contents for Legend 302