OM-4430 Page 17
5-4. Installing Exhaust Pipe
Ref 216 172
−
B / 803 891
Stop engine and let cool.
Engine backfire can cause se-
vere burns or other injuries.
Do not point exhaust pipe to-
ward control panel. Keep away
from exhaust outlet.
Point exhaust pipe in desired di-
rection but always away from
front panel and direction of travel.
Tools Needed:
1/2 in
5-5. Connecting To Weld Output Terminals
Stop engine.
Do not connect to CC and CV
terminals at the same time.
1
Negative (
−
) Weld Output
Terminal
2
Stick/TIG (CC) Weld Output
Terminal
3
Wire /CV Weld Output Terminal
For MIG welding, connect work cable
to Negative (
−
) terminal and wire
feeder cable to Wire (CV) terminal.
For Stick welding, connect work
cable to Negative (
−
) terminal and
electrode holder cable to Stick/TIG
(CC) terminal.
For TIG welding, connect work cable
to Stick/TIG (CC) terminal and elec-
trode holder to Negative (
−
) terminal.
216 172
−
B / 803 984
−
A
3
2
1
Summary of Contents for Legend 302
Page 43: ...OM 4430 Page 39 218 723 B ...