![Miller I-24A Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/miller/i-24a/i-24a_owners-manual_1796023019.webp)
OM-186895 Page 15
5-4.
14-Pin Receptacle Information
Pin*
Pin Information
A
J
B
K
I
C
L
N
H
D
M
G
E
F
A
24 volts AC with respect to pin G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC output to remote control with respect to pin D.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control with respect to pin D.
F
Current feedback; 0 to 10 volts DC, 1 V/100 A
H
Voltage feedback; 0 to 10 volts DC, 1 V/10 arc volts
*The remaining pins are not used.
Ref. S-0004-A
1
Gun/Feeder Adapter
2
Gun Connector
Insert gun connector into adapter.
Tighten locking ring.
3
Weld Cable Terminal
4
Weld Cable From Welding
Power Source
5-5.
Connecting Welding Gun And Weld Cable
801 922-D
1
2
4
3
Tools Needed:
9/16, 5/8 in.
Summary of Contents for I-24A
Page 34: ...Notes...