OM-246 522 Page 18
4-8. Connecting 230 Volts Input Power For Diversion 180 Models
!
Installation must meet all Na-
tional and Local Codes
−
have
only qualified persons make
this installation.
!
Always connect green or
green/yellow conductor to
supply grounding terminal
first, and never to a line termi-
nal.
!
Special installation may be re-
quired where gasoline or
volatile liquids are present
−
see NEC Article 511 or CEC
Section 20.
.
The Auto-Line circuitry in this unit
automatically links the power
source to the primary voltage be-
ing applied, either 115 or 230
VAC.
1
Rating Label
Supply correct input power (see Sec-
tion 4-4).
2
Black And White Input
Conductor (L1 And L2)
3
Green Or Green/Yellow
Grounding Conductor
4
Input Power Cord.
5
Disconnect Device (switch
shown in the OFF position)
6
Disconnect Device Grounding
Terminal
7
Disconnect Device Line
Terminals
Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.
Connect input conductors L1 and L2
to disconnect device line terminals.
8
Over-Current Protection
Select type and size of over-current
protection using Section 4-4 (fused
disconnect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout
device, and place switch in the On
position.
9
Multi-Voltage Plug And Power
Cord Connector (NEMA 6-50P
Plug Shown)
For multi
−
voltage plug connections,
see Section 4-9.
10 Receptacle (NEMA 6-50R)
(Customer Supplied)
Connect plug to receptacle.
Ref. 805 476-A
L1
L2
230 VAC, 1
10
Tools Needed:
1
1
9
4
6
3
5
8
=GND/PE Earth
Ground
7
L1
L2
2