OM-257 798 Page 35
8-3. Setup Screen
1
Information Bar
Displays general information on power source,
location, asset number, serial number, and dis-
play language.
2
Purge Time
Displays the length of time gas will flow when
the purge button is pressed. Edit button allows
time length to be changed.
3
Weld Cable Setup
Displays length and diameter of positive and
negative weld leads, torch, and voltage feed-
back (VFB) method that are selected. Edit but-
ton allows these parameters to be changed.
4
Jog Speed
Displays the minimum and maximum Jog
speeds in inches per minute (IPM). Edit button
allows minimum and maximum jog speed set-
ting to be changed for forward and reverse jog.
5
Ethernet Settings
Edit button allows user to change connectivity
settings.
6
Auto Thread
Displays the Load Rate in inches per minute
(IPM) and Torch Length (Inches) to determine
the length of time for Auto Threading. Edit but-
ton allows these parameters to be changed.
7
Status
Displays the status of Insight software. Edit
button allows that status to be changed.
1
2
5
3
4
7
6
8-4. Arc Management Screen
1
Active Program
Displays the program number, process, wire
size and alloy, and gas. Edit button allows these
parameters to be changed.
2
Commands
Displays current user changeable commands.
Depending on the weld process being used
these commands will vary. Edit button allows pa-
rameters to be changed.
3
Weld Sequence
Displays active weld sequence parameters. Edit
button allows changes to these parameters.
4
Lock Status
Displays the current status of system locks. Edit
button allows the lock configuration to be
changed.
5
Program Enable
Edit button will allow user to select which pro-
grams are available for use.
6
Advanced Triggers
Displays the current status of advanced trigger
modes. Edit button allows status of trigger
modes to be changed.
7
Program Naming
Edit button allows program Machine Display and
Description to be changed for each numbered
program.
8
Weld Processes
Displays available weld processes. Edit button
allows processes to be enabled or disabled.
1
4
2
3
5
6
7
8
Summary of Contents for Continuum 350
Page 17: ...OM 257 798 Page 13 Notes...
Page 27: ...OM 257 798 Page 23 Notes...
Page 45: ...OM 257 798 Page 41 Notes...
Page 47: ...OM 257 798 Page 43 264 238 B...
Page 48: ...OM 257 798 Page 44 Figure 10 2 Circuit Diagram For Continuum 350 Model Page 2 of 2...
Page 49: ...OM 257 798 Page 45 264 238 B...
Page 50: ...OM 257 798 Page 46 Figure 10 3 Circuit Diagram For Contiuum 500 Model Page 1 of 2...
Page 51: ...OM 257 798 Page 47 265 841 B...
Page 52: ...OM 257 798 Page 48 Figure 10 4 Circuit Diagram For Continuum 500 Model Page 2 of 2...
Page 53: ...OM 257 798 Page 49 265 841 B...
Page 62: ...OM 257 798 Page 58 Notes...