OM-259 355 Page 28
5-14. Selecting Weld Cable Sizes*
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Output
Terminals
!
Stop engine before
connecting to weld
output terminals.
!
Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10
−
60%
Duty
Cycle
60
−
100%
Duty
Cycle
10
−
100% Duty Cycle
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
Ref. S-0007-J 2011
−
07
5-15. Connecting To Remote 14 Receptacle RC14
Rmt14_1 2010
−
04
Accessories depend
on unit capabilities.
*The remaining sockets
are not used.
OR
Socket*
Socket Information
Not all models have contactor control. See description of front panel controls and
circuit diagram.
24 VOLTS AC
A
24 volts AC. Protected by supplementary protector.
B
Contact closure to A completes 24 volt AC contactor
control circuit.
REMOTE
OUTPUT
CONTROL
C
Output to remote c10 volts DC in MIG mode;
0 to +10 volts DC in Stick or TIG mode.
D
Remote control circuit common.
E
DC input command signal: 0 to +10 volts from min.
to max. of remote control with Voltage/Amperage
Adjust control at maximum.
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 and 115 volt AC circuit.
Summary of Contents for Big Blue 300 PRO Series
Page 33: ... Complete Parts List is available at www MillerWelds com OM 259 355 Page 29 Notes ...
Page 51: ... Complete Parts List is available at www MillerWelds com OM 259 355 Page 47 Notes ...
Page 59: ...OM 259 355 Page 55 240 670 C ...
Page 60: ...OM 259 355 Page 56 Figure 10 2 Circuit Diagram For Welding Generator With Kubota Engine ...
Page 61: ...OM 259 355 Page 57 253 845 B ...
Page 62: ...OM 259 355 Page 58 Figure 10 3 Circuit Diagram For Welding Generator With Mitsubishi Engine ...
Page 63: ...OM 259 355 Page 59 250 149 B ...
Page 74: ...OM 259 355 Page 70 Notes ...