OM-228 874 Page 38
1
Process Control Module PC4
Diagnostic LEDs are visible inside unit,
located on PC4 mounted on the top tray.
Refer to Section 8-5 for information on
diagnostic LEDs.
Reinstall cover after checking diagnostic
LEDs.
216 956-A / 248 891-A
8-4. Process Control Module PC4 Diagnostic LEDs
1
LED2
LED1
LED4
LED3
8-5. Diagnostic LEDs On Process Control Module PC4
LED
Status
Diagnosis
1
On
Indicates
−
25 volts DC is present on process control module PC4
Off
Indicates
−
25 volts DC is not present on process control module PC4
2
On
Ind25 volts DC is present on process control module PC4
Off
Ind25 volts DC is not present on process control module PC4
3,4
On
See Network Status Table in Section 8-10
Off
See Network Status Table in Section 8-10