OM-222 394 Page 25
SECTION 7
−
SETTING SEQUENCE PARAMETERS
7-1. Sequence Parameters In A Program
.
For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
6-8.
Weld Time can only be set by using
an optional PDA with File
Management/WaveWriter software.
If time is set to zero in any timed
sequence, the sequence is skipped.
.
Maximum IPM may actually be
lower depending on the process
and wire type selection.
Trigger
Pressed
Trigger
Released
Start
Time
Preflow
Weld
Crater
Time
Postflow
Start
Time
Time
Postflow
Crater
Weld
Preflow
Sequence
End
Volts/Arc
Adjust
IPM
Seconds
2. Postflow
Off-5.0
1. Preflow
Off-5.0
Sequence
Parameters
3. Start
4. Crater
Off-5.0
Off-5.0
10.0-44.0/
0-99
40-1400
10.0-44.0/
0-99
40-1400
Summary of Contents for 394F
Page 4: ......
Page 34: ...OM 222 394 Page 30 SECTION 9 ELECTRICAL DIAGRAM Figure 9 1 Circuit Diagram...
Page 35: ...OM 222 394 Page 31 218 564 D...
Page 42: ...Notes...