OM-235 464 Page 7

12. Routine Maintenance

!

Disconnect power 

before maintaining.

n

 = Check

Z

 = Change

~

 = Clean



= Repair

l

 = Replace

* To be done by Factory Authorized Service Agent

Every

3

Months

 

~

Coolant Filter, durning heavy

service, clean more frequently.

~

 Blow out heat exchanger fins.

n

Check coolant level. Top off with

     distilled or deionized water if necessary.

Every

6

Months

nl

Hoses

nl

 Labels

Z

Replace coolant.

13. Coolant Maintenance

805 191-A

!

Disconnect input power be-

fore maintaining.

NOTICE 

 Do not run cooler with-

out coolant in tank.

1

Coolant Filter

Unscrew housing to clean filter (see

Section 12).
Assemble and install cleaned cool-

ant filter.

.

Dispose of used coolant and
fluids in an environmentally

safe way.

Changing coolant: Drain coolant by

removing cap and tipping unit for-

ward, or use suction pump. Fill with

clean water and run for 10 minutes.

Drain and refill with coolant (see

section 9). Install cap.

.

If replacing hoses, use hoses

compatible with ethylene gly-

col, such as Buna-n, Neo-

prene, or Hypalon. 

Oxy-acety-

lene hoses

 are not compatible

with any product containing

ethylene glycol.

1

Summary of Contents for 300360001

Page 1: ...ecycler ou liminer tout liquide de refroidissement us conform ment aux m thodes prescrites pour assurer la protection de l environnement CALIFORNIA PROPOSITION 65 WARNINGS Welding or cutting equipment...

Page 2: ...ater Cooled GTAW Torches And GMAW Guns Used Primarily With Maxstar 200 Dynasty 200 And Syncrowave 200 Models IP Rating 23 Not Intended For Use In Heavy Rain Or Near Splashing Water 1 gal 3 8 L Coolant...

Page 3: ...on 8 Recycle or dispose of used coolant in an environmentally safe way 9 Do not remove or paint over cover the label 4 96 S 178 910 043 810 HF 043 809 AL 100 h std 2 1 3 6 4 7 5 1 Warning Watch Out Th...

Page 4: ...acility Contact your local recycling office or your local distributor for further information 9 Coolant Chart Low Conductivity Coolant No 043 810 Distilled Or Deionized Water OK Above 32 F 0 C Low Con...

Page 5: ...t tempt to rewire for 115 volts For 115 volt models an individual branch circuit capable of carrying 15 amperes and protected by fuses or circuit breakers is recommended Recommended fuse or cir cuit b...

Page 6: ...cut plug from 230 volt cord and at tempt to rewire for 115 volts An individual branch circuit capable of car rying 15 amperes and protected by fuses or circuit breakers is recommended Rec ommended fu...

Page 7: ...t input power be fore maintaining NOTICE Do not run cooler with out coolant in tank 1 Coolant Filter Unscrew housing to clean filter see Section 12 Assemble and install cleaned cool ant filter Dispose...

Page 8: ...r mid plane Coolant system does not work Be sure input power cord is plugged into an energized receptacle and power is turned on Check line fuses or circuit breaker and replace or reset if necessary M...

Page 9: ...OM 235 464 Page 9 Notes...

Page 10: ...4 Page 10 SECTION 16 PARTS LIST Hardware is common and not available unless listed 805 266 A 1 2 3 4 5 13 6 8 7 12 9 10 12 11 13 6 15 14 13 6 14 18 17 21 22 23 24 18 26 25 20 19 16 27 Figure 16 1 Main...

Page 11: ...Rbr Brd No 1 X 375 ID X 9 0 Black 1 15 235461 Damper Fluid Pulsation 1 16 MOT 235457 Pump Assy Coolant 115V 1 16 MOT 235501 Pump Assy Coolant 230V 1 17 PLG1 192457 Cable Power 11 Ft 7 In 16ga 3c 115V...

Page 12: ...atibility Standards IEC 60974 1 2005 Arc welding equipment Part 1 Welding power sources IEC 60974 2 2007 Arc welding equipment Part 2 Liquid cooling systems IEC 60974 10 2007 Arc Welding Equipment Par...

Page 13: ...Notes...

Page 14: ...Notes...

Page 15: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Page 16: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Reviews: