OM-287348 Page 29
5-7. Variable Inductance Settings
956172373_12-A
2
1
Parameter Settings Soft Key
2
Ampere/WFS Control Knob
Use knob to adjust parameter value.
While in Manual MIG mode, press parame-
ter settings soft key to enter parameter set-
tings. Press parameter settings soft key
again to enter inductance settings. Use
knob to adjust value from min
−
50% to max
50% in synergic MIG, and from min 25% to
max 200% in manual MIG.
Lower inductance is used for most short
arc applications. Higher inductance is
used for stainless steel and spray arc
applications.
Press parameter settings soft key to contin-
ue. Parameter settings will be displayed on
the screen. Press home soft key to return to
home screen.
Turn knob
to adjust value
1
Press to
return
to home screen
Press to
return
to home screen
Press to
continue
Press to
continue
Voltage
Notes
Summary of Contents for 059015051