OM-287469 Page 8
4-4. Cooler Connections
1
400 volt, 1 Amp AC Receptacle
2
400 volts AC Cord
Provides 115 VAC to power cooler.
3
7-Pin Receptacle (See Section 4-5)
Provides the following signals:
•
Signal to activate the cooler
•
Check for the presence of coolant flow
•
Check the presence of the cooler.
95617374-6-A
3
1
2
4-5. 7-Pin Rear Cable Cord Plug Information
956172374_1-A
7-Pin
Pin
Pin Information
AWC CONTROL
1
Common
2
Automatic Water Cooler Control
3
Not Used
4
Automatic Water Cooler Protection
5
Common
6
Not Used
7
(GND) Not Used
4-6. 4-Pin Rear Cable Cord Plug Information
956172374_1-A
4-Pin
Pin
Pin Information
AWC SUPPLY
1
Power Supply 400 volts AC
3
Power Supply 400 volts AC
2
Not Used
4
Earth Lead
Summary of Contents for 058042005
Page 4: ......
Page 15: ...OM 287469 Page 11 SECTION 7 ELECTRICAL DIAGRAM Ref 956172383 A...
Page 18: ...OM 287469 Page 14 Notes...