OM-1085 Page 12
A. Remote Start/Stop Switch
For the remote start/stop switch to work, the Mode switch must be in the RUN
position.
NOTE
Connect leads from normally-closed switch to terminals 2T21 and 2T22.
B. Remote Dwell On Left Control
Remove jumper link between 2T24
and 2T51.
Connect leads from remote control
to 2T9 and 2T24.
Rear
24
9
C. Remote Dwell On Right Control
Remove jumper link between 2T26
and 2T52.
Connect leads from remote control
to 2T9 and 2T26.
Rear
9
26
D. Remote Travel Width Control
If multiple Travel Width remote controls are desired, they must be switched using
relays with gold alloy cross bar type contacts or equivalent.
NOTE
Remove jumper links between
1T13 and 1T14, and 1T12 and
1T49.
Connect leads from remote control
to 1T12, 1T13, and 2T9.
Rear
9
13
12