OM-252 203 Page 26
7-3.
Cleaning Debris From Shielding Gas Filter Fitting
256 623-A
!
Disconnect power before
maintaining.
1
Shielding Gas Filter Fitting
Remove fitting from gas valve on
back panel of feeder.
Blow compressed air through the
threaded male end of fitting to dis-
lodge debris from internal mesh
screen.
if blowing compressed air
through fitting does not clear
obstructions replace fitting.
Reinstall fitting into gas valve.
Tighten fitting to 250 in. lbs (28 N
⋅
m).
Rear View of Feeder
Tools Needed:
3/4 in.
1