OM-322 Page 14
1
2-10. Placing Jumper Links And Connecting Input Power
802 934 / Ref. 802 940
Check input voltage available at
site.
1
Jumper Link Label
Check label – only one is on unit.
2
Jumper Links
Move jumper links to match input
voltage.
3
Input And Grounding
Conductors
Select size and length using
Section 2-9.
4
Line Disconnect Device
Select type and size of overcurrent
protection using Section 2-9.
Reinstall side panel.
Y
Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
3/8 in
3/8, 1/2, 7/16 in
Tools Needed:
230 VOLTS
L
L
460 VOLTS
L
L
S-010 587-B
575 VOLTS
L
L
230 VOLTS
460 VOLTS
200 VOLTS
L
L
L
L
L
L
S-083 566-C
GND/PE
Earth Ground
3
2
L2 (V)
L1 (U)
4
L1
L2
GND/PE