OM-322 Page 13
2-8.
115 Volts AC Duplex Receptacle
802 933
Y
Turn Off power before con-
necting to receptacle.
1
115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 4-2).
Power output is shared between
this receptacle and the Remote 14
receptacle (see Section 2-7).
1
2-9.
Electrical Service Guide
60 Hz
Input Voltage
200
230
460
575
Input Amperes At Rated Output
105
91
45
36
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Circuit Breaker
1
, Time-Delay
2
125
110
50
45
Normal Operating
3
150
125
70
50
Min Input Conductor Size In AWG/Kcmil
4
6
8
10
Max Recommended Input Conductor Length In Feet (Meters)
116
(35)
103
(31)
273
(83)
286
(87)
Min Grounding Conductor Size In AWG/Kcmil
6
6
8
10
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).