A complete Parts List is available at www.MillerWelds.com
OM-230 693 Page 24
SECTION 5 − OPERATION
5-1.
Controls
226 647-B
1
Voltage Control
Turn control clockwise to increase
voltage.
2
Wire Speed Control
Turn control clockwise to increase wire
feed speed.
3
Voltmeter
4
Wire Feed Speed Meter
2
3
.
This unit has three automatic timers included in its operation to help save contact
tips, gas, and wire:
Tip Saver − Weld output shuts off if tip is shorted to work surface.
Safety shut-off − Weld output will shut off if no arc is detected within 3 seconds after
gun trigger is depressed.
Jog mode − When loading a new roll of wire or if the gun trigger is accidentally
pressed, gas will shut off after 1 minute and wire will shut off after 2 minutes saving
wire and gas.
1
4